Mechatronic Analog Timer

 H3AM

3

Characteristics

Note:

A separately sold waterproof packing (Y92S-35) is necessary to ensure IP65 waterproofing between the Timer and installation panel. 
The H3AM-NS

@

-

@

-300 model with waterproof packing is available.

Accuracy of operating time

±

0.7% FS max.

Setting error

±

2% FS max.

Reset time

Power reset: 

0.5 s max.

Reset input time: 0.5 s max.

Influence of voltage

±

1% FS max.

Influence of temperature

±

2% FS max.

Insulation resistance

100 M

 max. (at 500 VDC)

Dielectric strength

2,000 VAC (50/60 Hz) for 1 min between exposed non-current-carrying metal parts and current-carrying metal parts
2,000 VAC (50/60 Hz) for 1 min between the operating circuit and control output terminals
1,000 VAC (50/60 Hz) for 1 min between the operating power supply circuit and reset input circuit (H3AM-NSR only)
1,000 VAC (50/60 Hz) for 1 min between contacts not located next to each other
2,000 VAC (50/60 Hz) for 1 min between contacts of opposite poles

Impulse withstand voltage

3 kV between power terminals
4.5 kV between exposed non-current-carrying metal parts and current-carrying metal parts

Noise immunity

±

1.5 kV (between power terminals) square-wave noise by a noise simulator 

(pulse width: 100 ns/1 

µ

s, 1-ns rise)

Static immunity

Malfunction: 8 kV
Destruction: 15 kV

Vibration resistance

Destruction:  10 to 55 Hz, 0.75-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)

Shock resistance

Destruction: 300 m/s

3 times each in 6 directions

Malfunction: 150 m/s

2

 (100 m/s

2

 in the front/back direction) 3 times each in 6 directions

Life expectancy

Mechanical:  5,000,000 times min. (under no load at 1,800 times/h)
Electrical: 

100,000 times min. (5-A at 250 VAC, resistive load at 1,800 times/h)

Motor life expectancy

20,000 h

EMC

(EMI): EN61812-1
Emission Enclosure: 

EN55011 class A

Emission AC Mains: 

EN55011 class A

(EMS): EN61812-1
Immunity ESD: 

IEC61000-4-2: 6 kV contact discharge

8 kV air discharge

Immunity RF-interference: 

IEC61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) 

10 V/m (Pulse-modulated, 900 MHz

±

5 MHz)

Immunity Power Frequency Magnetic Fields:  IEC61000-4-8: 30 A/m (50 Hz)
Immunity Conducted Disturbance: 

IEC61000-4-6: 10 V (0.15 to 80 MHz)

Immunity Burst: 

IEC61000-4-4: 2 kV power-line

2 kV I/O signal-line

Immunity Surge: 

IEC61000-4-5: 1 kV line to line 

2 kV line to ground

Enclosure rating

IP65 (front panel only) (See note.) IP20 (terminal section)

Weight

Approx. 350 g

Содержание H3AM

Страница 1: ...ilt in instantaneous contact NS Memory retention NSR Finger protection terminal block Enables easy sequence checks through instantaneous outputs for a zero set value at any time range Model Number Legend Ordering Information List of Models Note The operation of the instantaneous contacts differs for the self resetting and electric resetting systems Refer to Timing Charts on page 5 for details H3AM...

Страница 2: ...onforms to EN61812 1 IEC60664 1 4 kV 2 VDE0106 P100 Output category according to IEC60947 5 1 Model Full scale on dial Set time unit s 10 s min 10 min h hour 10 h hour H3AM A 3 0 5 to 30 s 0 05 to 3 min 0 5 to 30 min 0 05 to 3 h 0 5 to 30 h H3AM B 6 1 to 60 s 0 1 to 6 min 1 to 60 min 0 1 to 6 h 1 to 60 h H3AM C 12 0 2 to12 s 2 to 120 s 0 2 to 12 min 2 to 120 min 0 2 to 12 h Rated supply voltage 10...

Страница 3: ...inals square wave noise by a noise simulator pulse width 100 ns 1 µs 1 ns rise Static immunity Malfunction 8 kV Destruction 15 kV Vibration resistance Destruction 10 to 55 Hz 0 75 mm single amplitude for 2 cycles each in 3 directions 8 min per cycle Malfunction 10 to 55 Hz 0 5 mm single amplitude for 2 cycles each in 3 directions 8 min per cycle Shock resistance Destruction 300 m s2 3 times each i...

Страница 4: ...r Instantaneous or Time limit Output Selector for R2 Relay only for H3AM NS models Default setting is time limit output Time Unit Selector Illustrated Model H3AM C Note The scale goes up to 3 with the H3AM A and up to 6 with the H3AM B Model Applicable time unit Full scale on dial s 10 s min 10 min h 10 h H3AM A H3AM B H3AM C 3 6 12 No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes...

Страница 5: ... contact NO 6 8 Power indicator POWER Output indicator UP Reset 9 10 t t t t Rt Rt Note 1 The R2 contacts 7 8 and 6 8 are programmable and can be set to either instantaneous or time limit contacts using the switch located on the bottom of the Timer 2 Rt is the reset time and t is the set time Note t is the set time Rt is the reset application time and t is the power interruption time H3AM NS H3AM ...

Страница 6: ... 27 5 dia Four 5 dia holes Mounting Holes 70 0 4 96 81 dia hole Note Tightening torque for panel mounting is as follows 300 m N m 50 m N m Y92S 35 Note Use Waterproof Packing to provide a level of water protection that complies with IP65 standards Depending on the operating environment the Waterproof Packing may deteriorate contract or harden and so regular replacement is recommended 1 2 3 4 5 6 7...

Страница 7: ... malfunction or outputs may be unstable Precautions for Correct Use Changing Switch Settings Be sure to adjust the time unit selector and instantaneous or time limit output selector for R2 relay only before the Timer is turned ON otherwise the Timer may be damaged or malfunction Be sure to set the time only when Timer has stopped otherwise the Timer may malfunction Setting the Operating Time Do no...

Страница 8: ...ANTY NEGLIGENCE OR STRICT LIABILITY In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINAT...

Отзывы: