9 - 3
9 Adjustment Functions
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
9-1 Gain
Adju
stm
e
nt
9
9-1-3 Gain
A
d
justment Pro
c
edure
To improve machine rigidity:
• Install the machine on a secure base so that it does not have any play.
• Use couplings that have a high rigidity, and that are designed for servo systems.
• Use a wide timing belt, and use a tension within the range of allowable axial load for the motor or
decelerator output.
• Use gears with small backlash.
The specific vibration (resonance frequencies) of mechanical systems has a large impact on the gain
adjustment of the servo. The servo system responsiveness cannot be set high for machines with a
low resonance frequency (low machine rigidity).
9-1-3
Gain Adjustment Procedure
Gain Adjustment and Machine Rigidity
Start adjustment.
Automatic
adjustment?
Operation OK?
Yes
Yes
No
Operation OK?
Yes
No
No
Realtime autotuning
Realtime autotuning
settings
Manual tuning
Adjustment completed.
Write to EEPROM.
Consult OMRON.
(Default setting)
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......