8 - 3
8 Operation
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
8-2 Preparin
g f
o
r Operation
8
8-2
-1 Items to Che
c
k Bef
or
e T
ur
ning ON the
P
o
w
e
r Supply
8-2
Preparing for Operation
This section explains the procedure to prepare the Servomotor and Servo Drive for operation on
completion of installation and wiring. It explains items to check both before and after turning ON the
power supply.
• Check to be sure that the power supply voltage is within the ranges shown below.
R88D-KP01H/02H/04H/08H/10H/15H (Single-phase or single-phase/3-phase 200 VAC input)
Main circuit power supply: Single-phase or single-phase/3-phase 200 to 240 VAC (170 to 264 VAC)
50/60 Hz
Control circuit power supply: Single-phase 200 to 240 VAC (170 to 264 VAC) 50/60 Hz
R88D-KP20H/30H/50H (3-phase 200 VAC input)
Main circuit power supply: 3-phase 200 to 230 VAC (170 to 253 VAC) 50/60 Hz
Control circuit power supply: Single-phase 200 to 230 VAC (170 to 253 VAC) 50/60 Hz
• The main circuit power supply inputs (L1/L3 or L1/L2/L3) must be properly connected to the terminal
block.
• The control circuit power supply inputs (L1C/L2C) must be properly connected to the terminal block.
• The Servomotor’s red (U), white (V), and blue (W) power lines and the green/yellow (
) must be
properly connected to the terminal block.
• There should be no load on the Servomotor. (Do not connect the mechanical system.)
• The Servomotor side power lines and the power cables must be securely connected.
• The encoder cable must be securely connected to the encoder connector (CN2) of the Servo Drive.
• The encoder cable must be securely connected to the encoder connector of the Servomotor.
• The control cable must be securely connected to the control I/O connector (CN1).
• The Operation Command (RUN) signal is OFF.
8-2-1
Items to Check Before Turning ON the Power Supply
Checking Power Supply Voltage
Checking Terminal Block Wiring
Checking the Servomotor
Checking the Encoder Wiring
Checking the Control I/O Connector
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......