7 Parameter Details
7 - 58
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
Explanation of Set Values
• Select whether to write to the EEPROM when a parameter is changed from the front panel.
• Set the initialization time after turning ON the power supply to the standard 1.5 seconds plus the
specified value.
• Make fine adjustment to the encoder phase-Z width if the number of pulses per motor rotation after
pulse output dividing is not an integer.
• Do not set.
• Do not set.
• Do not set.
• Set the compensation gain for the disturbance torque.
• Set the filter time constant for disturbance torque compensation.
Pn617
Front Panel Parameter Write Selection
Setting
range
0 to 1
Unit
–
Default
setting
0
Cycle the
power supply
Required
Set value
Description
0
Writing to the EEPROM is not performed simultaneously with parameter changes.
1
Writing to the EEPROM is performed simultaneously with parameter changes.
Pn618
Power Supply ON Initialization Time
Setting
range
0 to 100
Unit
0.1 s
Default
setting
0
Cycle the
power supply
Required
Pn619
Encoder Phase-Z Setting
Setting
range
0 to 32,767
Unit
Pulses
Default
setting
0
Cycle the
power supply
Required
Pn620
Reserved
Setting
range
0
Unit
–
Default
setting
0
Cycle the
power supply
–
Pn621
Reserved
Setting
range
0
Unit
–
Default
setting
0
Cycle the
power supply
–
Pn622
Reserved
Setting
range
0
Unit
–
Default
setting
0
Cycle the
power supply
–
Pn623
Disturbance Torque Compensation Gain
Setting
range
–100 to 100
Unit
%
Default
setting
0
Cycle the
power supply
–
Pn624
Disturbance Observer Filter Setting
Setting
range
10 to 2,500
Unit
0.01 ms
Default
setting
53
Cycle the
power supply
–
All
All
All
Position
Position
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......