6 Applied Functions
6 - 38
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
6-10 Forward and Reverse Drive
Prohibition Functions
• If the Forward Drive Prohibition Input (POT) or Reverse Drive Prohibition Input (NOT) is turned OFF,
the motor will stop rotating.
• You can thus prevent the Servomotor from rotating outside of the operating range of the device by
using limit inputs from the device connected to the Servo Drive.
These parameters are allocated by default as follows.
• Refer to 6-9 Sequence I/O Signals on page 6-33 for details about Input Signal Selection 1 to 10.
6-10-1 Outline of the Function
6-10-2 Parameters Requiring Settings
Parameter
No.
Name
Description
Reference
Pn400 to
Pn409
Input Signal Selection 1 to 10 Set the input signal allocations and logic.
These parameters are allocated by default as
follows.
Pn400 (CN1 pin 8): NOT (Logic contact NC)
Pn401 (CN1 pin 9): POT (Logic contact NC)
Pn504
Drive Prohibition Input
Selection
Set the operation to be performed when the
Forward and Reverse Drive Prohibition Input
signal turns ON.
Pn505
Stop Selection for Drive
Prohibition Input
Set the deceleration and stop methods used when
the Forward and Reverse Drive Prohibition Input
signal turns ON.
Input Signal Selection Function (Default Settings: Pn400, Pn401)
Parameter No.
Name
Default setting
Set value
Position control
Speed control
Pn400
Input Signal Selection 1
00828282
NOT (NC)
NOT (NC)
Pn401
Input Signal Selection 2
00818181
POT (NC)
POT (NC)
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......