84
Controller Status Read
Section 6-9
6-9
Controller Status Read
This service reads the operating status and error status.
Command
Response
Operating Status
Related Information
Response Code
Example:
Command: [STX]010000601[ETX][BCC]
Response: [STX]010000060100000000[ETX][BCC]
"01"
MRC
2
SRC
2
"06"
"01"
MRC
2
SRC
2
"06"
4
2
2
Response code
Operating
status
Related
information
Operating status
Meaning
“00”
Operating (when operating status is read in Monitor
Level or Adjustment Level and an error has not
occurred)
“01”
Stopped (other conditions)
7
6
5
4
3
2
1
0
ON when operation is
stopped for an error.
Meaning
1: Error
---
---
---
---
---
---
---
Error status
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Response code
Error name
Cause
“1001”
Command length too long
The command is too long.
“0000”
Normal end
Processing was completed
normally.