83
Controller Attribute Read
Section 6-8
6-8
Controller Attribute Read
This command reads the model number of the Controller and the communica-
tions buffer size.
Command
Response
Model Number
Buffer Size
The buffer size is 113 bytes (=071 hex).
Response Code
Example: The following response would be returned for a model with a 45-A
rating.
Command: [STX]010000503[ETX][BCC]
Response: [STX]01000005030000G3PW-A12030071[ETX][BCC]
"03"
MRC
2
SRC
2
"05"
"05"
Model number
MRC
2
SRC
2
4
10
"03"
4
"G3PW- "
Buffer size
Response code
"0071"
Number
Code
Meaning
A
“A”
Constant Current
B
“1”
Always 1.
C
“0”
20 A
“1”
30 A
“2”
45 A
“3”
60 A
D
“0”
Always 0.
E
“3”
Always 3.
G
3
P
W
–
4
1
2
3
5
Response code
Error name
Cause
“1001”
Command length too long
The command is too long.
“0000”
Normal end
Processing was completed
normally.
Содержание G3PW
Страница 1: ...Cat No Z280 E1 01 User s Manual G3PW Power Controllers...
Страница 2: ...G3PW Power Controllers User s Manual Produced November 2008...
Страница 3: ...iv...
Страница 15: ...xvi...
Страница 49: ...34 Wiring for Specific Applications Section 3 4...
Страница 61: ...46 Setting Parameters in the Initial Setting Level Section 4 6...
Страница 77: ...62 Heater Burnout Detection Section 5 9...
Страница 113: ...98 Parameter Settings in the Adjustment Level Appendix B...
Страница 117: ...102 Index...
Страница 119: ......