Control/Output through EtherNet/IP
FZ4 User's Manual
Control/Output through EtherNet/IP
This section explains how to set the required communication specifications when using EtherNet/IP to
communicate with external devices.
EtherNet/IP is a multi-vendor network for the industrial community using Ethernet that is managed by
ODVA (Open DeviceNet Vender Association).
A cyclic communication (tag data link communication) with an EtherNet/IP device that supports the class
1 communication of the EtherNet/IP standard can be achieved without a user program. Using the tag
data link communication, FZ4 sends and receives data that is the same as the parallel interface to and
from an external device.
The message communication function is used when communicating with a PLC that does not support
tag data link communication or when using functions, such as character string output, that are not
supported in tag data link communication. Message communication can be performed either by
exchanging the same data as for tag data link communication using AssemblyObjects or by sending and
receiving commands equivalent to non-procedure commands using FZ4-specific VisionSystemObjects.
EtherNet/IP communication specification
The EtherNet/IP communication specification is described. The conformance test applies to Ver.A7.
Before establishing the communication, specify the output and input connection settings on the external
device. For details, refer to the Instruction Manual of the device being used.
Output connection
Item
Setting description
Communication direction
Originator
→
Target (FZ4)
Data size
[Note]
20 bytes (Command area)
Input connection
Item
Setting description
Communication direction
Target (FZ4)
→
Originator
Data size
[Note]
48 bytes (Response area + Data Output area)
[Note]: Up to 502 bytes of data can be set, but the current version should be used with 20 bytes (default)for
output connections and 48 bytes (default)for input connections.
Important
●
If instances are to be specified without using the EDS file, an AssemblyObject must be set as specified below.
When using the 2-line random trigger mode, be sure to set 102 and 103.
Setting of AssemblyObject
Parameter
name
Setting
value
Remarks
Instance ID
100
Output connection (for normal control and for line 0 in the 2-line random trigger
mode)
101
Input connection (for normal control and for line 0 in the 2-line random trigger mode)
102
Output connection (for line 1 in the 2-line random trigger mode)
103
Input connection (for line 1 in the 2-line random trigger mode)
Acesst 1.0 6251194
Содержание FZ4 Series
Страница 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Страница 12: ...1 Before Operation 10 Operation Flow FZ4 User s Manual Operation Flow Here describes the operation flow...
Страница 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Страница 112: ...3 Performing Test Measurement Starting Operation 110 Useful Functions for Operation FZ4 User s Manual...
Страница 326: ...4 Using Tool 324 Remotely Operating the Controller Remote Operation FZ4 User s Manual Enter the IP address...
Страница 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Страница 351: ...6 Changing the System Environment FZ4 User s Manual Setting the System Operation Environment 349 Communication...
Страница 566: ......
Страница 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Страница 654: ...652 FZ4 User s Manual...
Страница 655: ......