4
Using
Tool
FZ4 User's Manual
Using Custom Command
189
Change scene group number
ChangeSceneGroup <sceneGroupNo> , <sceneNo>
Parameters
<sceneGroupNo>
Scene group number to change(integer type)
<sceneNo>
Scene number to change(integer type)
Return Value
None.
Description
Change the scene group and the scene appointed with a <sceneGroupNo> and a <sceneNo>.
Example
Change to scene group 10.
ChangeSceneGroup 10 , 0
Check a registration state of the processing unit
CheckUnit (<unitNo>)
Parameters
<unitNo>
Unit number to check (integer type)
Return Value
Returns the value of the integer type.
The content of the value is the registration state.
0:Non-registration.
1:Registered
Description
Check whether is registered at the position where a processing item was appointed with an <unitNo>.
Example
When a processing unit is registered in unit 3, rearrange it for a processing item search.
if CheckUnit (3) = 1 then
Ident$ = "Search"
AssignUnit 3 , Ident$
endif
Acesst 1.0 6251194
Содержание FZ4 Series
Страница 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Страница 12: ...1 Before Operation 10 Operation Flow FZ4 User s Manual Operation Flow Here describes the operation flow...
Страница 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Страница 112: ...3 Performing Test Measurement Starting Operation 110 Useful Functions for Operation FZ4 User s Manual...
Страница 326: ...4 Using Tool 324 Remotely Operating the Controller Remote Operation FZ4 User s Manual Enter the IP address...
Страница 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Страница 351: ...6 Changing the System Environment FZ4 User s Manual Setting the System Operation Environment 349 Communication...
Страница 566: ......
Страница 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Страница 654: ...652 FZ4 User s Manual...
Страница 655: ......