3
Performing
Test
Measurement/Starting
Operation
FZ3 User's Manual
Key Points for Adjustment
67
Shortening Processing Time
Find out which processing units are taking the most time and adjust the parameters of these processing
items taking time.
1.
Insert the processing item "Elapsed Time" after the processing unit for which time is to be
measured.
2.
Execute measurement.
3.
After tapping the "Detail result" area, tap the elapsed time processing unit where time is to be
checked.
The elapsed time from the top of the flow to the relevant processing unit is displayed.
4.
Adjust the parameters of the processing units that are taking time.
For details on adjustment parameters, see "Key Points for Adjustment" for each processing item
in the Processing Item List Manual.