6
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
136
Communicating through Serial Communication (PLC Link)
FZ3 User's Manual
+4
—
0000
0000
0000
0000
Specify the scene No.
+5
—
0000
0000
0000
0000
Response (Controller to PLC)
Response
area
top channel
Bit
Description
15-12
11-8
7-4
3-0
+2
0001
0000
0000
0000
Command code
Store response target command codes.
+3
0000
0000
0011
0000
+4
0000
0000
0000
0000
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
+5
0000
0000
0000
0000
Switching Scene Groups
Switches the scene group No. to be used.
Command (PLC to Controller)
Command
area
top channel
Command
code
Bit
Description
15-12
11-8
7-4
3-0
+2
2000
0010
0000
0000
0000
Set command codes.
+3
0030
0000
0000
0011
0000
+4
—
0000
0000
0000
0000
Specify the scene group
No.
+5
—
0000
0000
0000
0000
Response (Controller to PLC)
Response
area
top channel
Bit
Description
15-12
11-8
7-4
3-0
+2
0010
0000
0000
0000
Command code
Store response target command codes.
+3
0000
0000
0011
0000
+4
0000
0000
0000
0000
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
+5
0000
0000
0000
0000
Acquiring Unit Data
Acquires the specified processing unit data.
Important
●
In Set Unit Data/Get Unit Data, external reference table No. 139 (verification string) of Character Inspection
cannot be used.
Acesst 1.0 6251194
Содержание FZ3 Series
Страница 10: ...1 Before Operation 8 Operation Flow FZ3 User s Manual Operation Flow Operation flow is explained here...
Страница 28: ...1 Before Operation 26 Saving Settings and Turning Power Off FZ3 User s Manual...
Страница 60: ...2 Setting Scenes Measurement Flow 58 Editing Scene Groups FZ3 User s Manual...
Страница 106: ...4 Saving Loading Data 104 Loading Settings Data to Controller FZ3 User s Manual...
Страница 122: ...5 Changing the System Environment 120 Setting the System Operation Environment FZ3 User s Manual...