Part Names and Functions
30
FQ2 User’s Manual
FQ2-S3
@
-
@@@
(Sensors with C-mounts)
No.
Name
Description
(1)
C-mount lens mounting surface The C-mount lens and macro ring are attached here. Determine the appro-
priate CCTV lens (C-mount lens) to use based on the field of view required
for the size of the measurement object.
Optical Diagrams: p. 35
(2)
I/O Cable connector
An FQ-WD or FQ-WU I/O Cable is used to connect the Sensor to the power
supply, external I/O, and Data Unit.
(3)
Ethernet Cable connector
An FQ-WN Ethernet Cable is used to connect the Sensor to external
devices such as the Touch Finder or computers.
(4)
Operation
indicators
OR
Lights orange when the overall judgement output (OR) signal turns ON.
ETN
Lights orange during Ethernet communications.
ERROR
Lights red when an error occurs.
BUSY
Lights green when the Sensor is executing a process.
* You can change the BUSY indicator to a RUN indicator.
This indicator is set by default to a BUSY indicator, but if you change it to a
RUN indicator, it will light green during operation.
Changing the Sensor’s BUSY Indicator: p. 231
(5)
Mounting holes
These mounting holes for M3 screws are used to mount the Camera and to
mount to the base. There are mounting holes on the top, bottom, left, and
right surfaces.
Dimensions: p. 477
(6)
Mounting base (enclosed)
The mounting base has 1/4-20UNC threads and is used to mount the Sen-
sor. The base can be attached to the bottom, top, left, or right side of the
Sensor.
* We recommend mounting the Sensor with the mounting screw holes. The
mounting base does not necessarily need to be used.
(7)
C-mount cover
This cover is attached to the C-mount lens fitting when a lens is not
attached.
(8)
Connector cover
This cover is attached to the connection when an Ethernet Cable is not con-
nected.
(1)
(4)
(7)
(
8
)
(3)
(2)
(6)
(5)
(5)
(5)
(5)
Bottom
Sensor Mo
u
nted to Base
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......