Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
FQ2 User’s Manual
271
8
Co
ntro
llin
g Operatio
n an
d Ou
tp
utti
ng Da
ta
with a Parall
el Con
nection
[Image]
−
[Camera setup]
−
[
]
−
[Lighting control]
1
Change the setting for lighting control.
When the strobe polarity is set to [Negative], a delay of about 200 to 300
μ
s occurs from when the TRIG signal
is input until the STGOUT signal goes low. When a high-speed shutter is used, set the [Output polarity]
parameter to [Positive].
• Timing Chart for Strobe Trigger Output Signal
The STGOUT signal turns ON in sync with the trigger input signal from an external device.
Controlling Operation from an External Device
The following Sensor functions can be controlled with command inputs from an external device without
connecting the Touch Finder.
Item
Parameter
Setting
Description
Lighting control
Strobe output delay 0 to 65,535
μ
s
(default: 0
μ
s)
Enter the delay time from when the TRIG signal is
input until the external lighting is lit.
Strobe output time
0 to 65,535
μ
s
(default: 1,000
μ
s)
Set the pulse width of the output signal (STGOUT)
that tells the external lighting when to light.
Operation
Description
Reference
Switching the scene
This command changes the scene when the line process changes.
Clearing measurement
values
This command clears the measurement values.
The OR signal and D signals are not cleared.
Clearing an error
This command turns the ERROR signal OFF.
The ERROR indicator is also turned OFF.
Re-registering the model
and reference color
This command re-registers the model and reference color.
Teaching
This command uses the image that is currently being input to execute
teaching for all of the registered items.
Clearing the OR and D sig-
nals
This command clears the OR signal and D signals.
Saving data in the Sensor
This command saves the current settings (scene data and system data)
in the Sensor.
Important
Trigger inp
u
t (TRIG)
Expos
u
re time
Imaging element
sh
u
tter signal
STGOUT
Trigger delay
Stro
b
e o
u
tp
u
t delay
Stro
b
e o
u
tp
u
t time
O
N
OFF
O
N
OFF
O
N
OFF
Polarity of all o
u
tp
u
t signals: Positi
v
e
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......