Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
FQ2 User’s Manual
259
8
Co
ntro
llin
g Operatio
n an
d Ou
tp
utti
ng Da
ta
with a Parall
el Con
nection
●
Reflecting Judgement Results to the Overall Judgement
You can specify whether to reflect the judgement result of a parallel judgement output in the overall judgement.
(The default is to reflect them.)
[In/Out]
−
[I/O setting]
−
[Output data set]
−
[Par. Jdg Output]
−
[Details] Tab Page
−
[Output
parameter]
−
[Reflect]
●
Stopping Data Output
You can also prevent the judgement results that are set from actually being output. (The default setting is [Yes].)
[In/Out]
−
[I/O setting]
−
[Output data set]
−
[Par. Jdg Output]
−
[Details] Tab Page
−
[Output
parameter]
−
[Data output]
●
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via Ethernet or used in
calculations.
Parallel Data Output
You can output the following data as 16-bit data by setting them as the output data (data 0 to data 31):
measurement data from inspection items that can be output and the calculation results from the expression
settings.
●
Setting the Data to Output
You can individually assign the parameters of the inspection items to output data (data 0 to data 31).
The following procedure shows how to assign the measured position X of [0. Search] to data 0 for a parallel
output.
[In/Out]
−
[I/O setting]
−
[Output data set]
−
[Par. Jdg Output]
−
[Basic] Tab Page
Expression text
string
Data name
Description
Data range
JG
Judgement
This is the judgement result.
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
D0 to D15
Data 0 to 15
These are the results of the expressions that are set
for output judgement data 0 to 15.
−
999,999,999.9999 to
999,999,999.9999
J00 to J15
Judgments 0 to 15
These are the judgement results of the expressions
that are set for output judgement data 0 to 15.
0: OK
−
1: NG
−
2: Not measured.
1
Press [Data settings].
2
Press [Data 0].
3
Press [I0. Search].
4
Press [Position X X].
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......