Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
236
FQ2 User’s Manual
Performing One Measurement for Each External Trigger
A measurement trigger is input as the TRIG signal from a proximity sensor, PLC, or other external device.
One measurement is performed when the TRIG signal turns ON.
Wiring
Timing Chart
1. Turn ON the TRIG signal while the BUSY signal is OFF.
2. Measurement begins and the BUSY signal is turned ON during the measurement process.
3. When the measurement has been finished, the measurement result is output using an OR signal, and the
BUSY signal is turned OFF.
*1
*1: You can also set the signal to be turned OFF after data logging, image logging, or displaying results in the [BUSY output].
When the Brightness Correction Mode is ON, the timing when images are taken is delayed.
Timing Chart When the Brightness Correction Mode Is ON: p. 61
Color
Signal
Description
The signals shown at the left are used.
Refer to the following information for signal wiring.
Wiring: p. 42
Pink
TRIG
Trigger signal
Black
OUT0 (OR)
Overall judgement (default
assignment)
Orange OUT1 (BUSY)
Processing in progress (default
assignment)
(2) Performs
meas
u
rements once
Trigger inp
u
t Sensor
Or other
de
v
ice
(1) TRIG signal O
N
OFF
O
N
OFF
O
N
T
u
rned O
N
w
hen o
v
erall j
u
dgement is
N
G.
(OR o
u
tp
u
t: O
N
for
N
G)
OR signal
O
N
w
hile meas
u
rements are
b
eing processed (depends
on BUSY o
u
tp
u
t conditions)
BUSY signal
TRIG signal
O
N
for 1 ms min.
Important
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......