Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
234
FQ2 User’s Manual
8-1 Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
Basic Operation with a Parallel Connection
This section describes the basic connections and signal flow with external devices.
With the default settings, the Sensor operates in the following manner.
*
You can also use the READY signal, which will turn ON when a measurement trigger can be input.
You can assign the READY signal to any output from OUT0 to OUT2.
(
Getting Individual Judgements and Expression Judgements: p. 241)
(2) Meas
u
rements
performed
(1) Meas
u
rement
trigger inp
u
t
(3) J
u
dgement
res
u
lts o
u
tp
u
t
Trigger Sensor
FQ2
V
ision Sensor
External de
v
ice
(3) J
u
dgement res
u
lts
o
u
tp
u
t (o
v
erall
j
u
dgement: OR
signal)
Retained
u
ntil the next
j
u
dgement res
u
lts are
o
u
tp
u
t.
T
u
rned O
N
w
hen o
v
erall j
u
dgement is
N
G.
(2) Exec
u
ting
meas
u
rement
processing
(BUSY signal)
This signal stays O
N
u
ntil the next
meas
u
rement trigger can
b
e inp
u
t.*
Yo
u
can confirm if meas
u
rements are in progress.
The trigger to perform meas
u
rements once is t
u
rned O
N
.
(1) Meas
u
rement
trigger inp
u
t
(TRIG signal)
O
N
OFF
O
N
OFF
O
N
w
hile meas
u
re-
ments are in progress
Meas
u
rement
trigger inp
u
t
(TRIG signal)
OFF
O
N
BUSY signal
OFF
O
N
OFF
O
N
READY signal
O
N
w
hile meas
u
rements are in progress
OFF
w
hile meas
u
rements are in progress
W
hen the meas
u
rement
trigger is recei
v
ed, the BUSY
signal t
u
rns O
N
and the
READY signal t
u
rns OFF.
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......