Outputting Data and Controlling Operation through EtherNet/IP
352
FQ2-S4 User’s Manual
Accessing Communications Areas Using Variables with NJ-series Controllers
With an NJ-series Controller, only variables can be used to access from the user program the I/O memory
addresses that are assigned to the communications areas.
Use the following settings.
●
Using Network Variables for Access
Create user-defined variables that match the structures of the communications areas of the Sensor.
Use the Sysmac Studio to define the variables.
Refer to the
Sysmac Studio Version 1 Operation Manual
(Cat. No. W504) for Sysmac Studio operating
procedures.
1
Defining the Data Types of the Variables
Define data types for variables that match the structures of the communications areas.
(1)
Defining a Data Type for Signal Access
First, define a BOOL array data type to access the control signals and status signals.
Here, a data type called “U_EIPFlag” is defined.
Name of data type: U_EIPFlag
Type of derivative data type: Union
(2)
Defining Data Types for Communications Area Access
Data types are defined to access the communications areas, with one data type for the command area
and another data type for the response and output areas.
Here, data types called “S_EIPOutput” and “S_EIPInput” are defined.
• Data Type to Access the Command Area
Name of data type: S_EIPOutput
Type of derivative data type: Structure
U_EIPFlag
F
UNION
Data type
Name of data type
ARRAY[0..31]OF BOOL
Specifies an array of
BOOL data from 0 to 31.
W
DWORD
32-bit bit string data
Name of data type
Data type
S_EIPOutput
STRUCT
ControlFlag
U_EIPFlag
The data type that was defined above (1)
CommandCode
DWORD
32-bit bit string data
CommandParam2
UDINT
32-bit integer data
CommandParam3
DINT
32-bit integer data
CommandParam1
UDINT
32-bit integer data
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......