Inspecting with the Search Inspection Item
138
FQ2-S4 User’s Manual
Step 2
Teaching
Teaching means to store the region and partial image as reference data for the measurement.
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Search]
−
[Settings] Tab Page
The following data is stored as the measurement reference.
Step 3
Adjusting Judgement Parameters
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Search]
−
[Settings] Tab Page
1
Press [Teach].
2
Place the object that is to be used as the measure-
ment reference in front of the camera.
3
Move the rectangle to the location to be measured.
4
Press [OK].
5
Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has
been completed.
6
Press [Back] to end teaching.
Item
Parameter
Description
Reference data
Model image
This is the partial image that is stored as the reference.
Reference position X
These are coordinates of the model image that are stored as reference.
Reference position Y
1
Press [Judgement].
2
Press each parameter and set the range that is to be
judged as OK. Set the range for each of the following
parameters.
Continuous measurements will be performed for the im-
ages that are taken.
3
Press [OK] to accept the value.
4
Press [Back] to end making the setting.
Parameter
Setting
Description
Correlation
Range: 0 to 100
Defaults: Lower limit: 60, Upper limit: 100
Adjust the upper and lower limits of the correlation for an OK judge-
ment.
Position X
Range:
−
99,999.9999 to 99,999.9999
Defaults: Lower limit:
−
99,999.9999,
Upper limit: 99,999.9999
Adjust the upper and lower limits of measurement position X for an
OK judgement.
Position Y
Range:
−
99,999.9999 to 99,999.9999
Defaults: Lower limit:
−
99,999.9999,
Upper limit: 99,999.9999
Adjust the upper and lower limits of measurement position Y for an
OK judgement.
Angle
Range:
−
180 to 180
Defaults: Lower limit:
−
180, Upper limit: 180
Adjust the upper and lower limits of angle for an OK judgement.
Count
Range: 0 to 32
Defaults: Lower limit: 0, Upper limit: 32
Adjust the upper and lower limits of the detection count for an OK
judgement.
Drag a corner to
size the rectangle.
Drag the rectangle
to move it.
Blue for OK. Red for NG.
Upper limit
Lower limit
If more than one result was detected, you
can switch to a display for each result.
(Multi-point output must be enabled.)
You can change the parameters for judgement conditions on the
Display Settings Display. Press
[
]
−
[Display setting] on the right
of the display to switch to the Display Settings Display.
Note
Содержание FQ2-S4
Страница 1: ...User s Manual Smart Camera FQ2 S4 Cat No Z330 E1 01 ...
Страница 58: ...Setting Up Ethernet 56 FQ2 S4 User s Manual MEMO ...
Страница 214: ...Calculations and Judgements Using Inspection Item Data 212 FQ2 S4 User s Manual MEMO ...
Страница 234: ...Adjusting Judgement Parameters during Operation 232 FQ2 S4 User s Manual MEMO ...
Страница 446: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 444 FQ2 S4 User s Manual MEMO ...
Страница 452: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 450 FQ2 S4 User s Manual MEMO ...
Страница 453: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 452 11 2 Error Messages 454 11 3 Basic Troubleshooting 455 ...
Страница 458: ...Basic Troubleshooting 456 FQ2 S4 User s Manual MEMO ...
Страница 591: ...Index FQ2 S4 User s Manual 589 Index 12 ...
Страница 593: ......