External Reference Parameters
FQ2-S/CH User’s Manual
529
Appe
ndi
ce
s
9
Shape Search II (FQ2-S1/S2/S3 series or FQ2-S4 series only)
800
Mea-
sure-
ment
result
display
Position X display pat-
tern
Set / Get 0: Absolute value
1: Relative value
0
---
---
801
Position Y display pat-
tern
Set / Get 0: Absolute value
1: Relative value
0
---
---
802
Measured angle dis-
play pattern
Set / Get 0: Absolute value
1: Relative value
0
---
---
1000+N
(N=0 to
99)
Mea-
sure-
ment
result
Sub-region correlation
N
Get only
0 to 100
0
CRN
---
1100+N
(N=0 to
99)
Sub-region density
deviation N
Get only
Sub-region density deviation N
0
DVN
---
External
refer-
ence
number
Category Data name
Set / Get Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
0
Mea-
sure-
ment
result
Judgement
Get only
−
2: No judgement (not mea-
sured),
0: Judgement is OK,
−
1: Judgement is NG,
−
13: Teaching not performed
error,
−
14: Figure not registered error,
−
15: Out of range error
−
2
JG
Logged data
5
Correlation
Get only 0 to 100
0
CR[0] to
CR[31]
Logged data
6
Position X
Get only
−
99,999.9999 to 99,999.9999
0
X[0] to
X[31]
Logged data
7
Position Y
Get only
−
99,999.9999 to 99,999.9999
0
Y[0] to
Y[31]
Logged data
8
Angle
Get only
−
180 to 180
0
TH[0] to
TH[31]
Logged data
9
Mea-
sure-
ment
result
Reference X
Get only
−
99,999.9999 to 99,999.9999
0
SX
---
10
Reference Y
Get only
−
99,999.9999 to 99,999.9999
0
SY
---
11
Reference angle
Get only
−
180 to 180
0
ST
---
12
Detection coordinate X
Get only
−
99,999.9999 to 99,999.9999
0
RX
---
13
Detection coordinate Y
Get only
−
99,999.9999 to 99,999.9999
0
RY
---
14
Count
Get only 0 to 32
0
C
Logged data
103
Output
parame-
ter
Reflect
Set / Get 0: Yes
1: No
0
---
---
120
Model
region
Rotation
Set / Get 0: Yes
1: No
0
---
---
121
Rotation angle upper
limit
Set / Get
−
180 to 180
180
---
---
122
Rotation angle lower
limit
Set / Get
−
180 to 180
−
180
---
---
External
refer-
ence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...