External Reference Parameters
502
FQ2-S/CH User’s Manual
Linear Correction
OCR (FQ2-S4 or FQ2-CH series only)
External
refer-
ence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
0
Mea-
sure-
ment
result
Judgement
Get only
−
2: No judgement (not measured)
0: Judgement is OK
−
1: Judgement is NG
−
2
JG
---
120
Mea-
sure-
ment
condi-
tions
Position interpolation
Set / Get
0: None, 1: Bilinear
1
---
---
122
Source image
Set / Get
0: Camera image, 1: Previ-
ous image
1
---
---
Exter-
nal ref-
erence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
0
Mea-
sure-
ment
result
Judgement
Get only
−
2: No judgement (not measured)
0: Judgement is OK
−
1: Judgement is NG
-11: Model mismatch error
-13: Teaching not performed error
−
16: Measurement timeout error
−
17: Format not entered error
−
2
JG
Logged data
5
Index number
Get only
−
2: No verification pattern
or read was NG,
−
1: Verification result is NG
0 to 31: Master data number
0
IN
Logged data
6
Number of characters
Get only 0 to 128
0
N
Logged data
7
Read character string
Get only 128 characters max.
--
---
8
Similarity
Get only 0 to 100
0
SIM
Logged data
9
Stability
Get only 0 to 100
0
STB
Logged data
103
Output
parame-
ter
Reflect
Set / Get 0: Yes
1: No
0
---
---
110
Reading speed
Set / Get 0: Normal
1: Fast
0
---
---
120
Mea-
sure-
ment
condi-
tions
Character color
Set / Get 0: Black
1: White
0
---
---
121
Dot horizontal interval
Set / Get 0 to 30
0
---
---
122
Dot vertical interval
Set / Get 0 to 30
0
---
---
123
Character thickness
threshold
Set / Get
−
128 to 128
0
---
---
124
Boundary correction
Set / Get 0: OFF
1: ON
1
---
---
126
Slender character thresh-
old
Set / Get 1 to 10
3
---
---
127
Hyphen height upper
threshold
Set / Get 0 to 100
30
---
---
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......