put OUT0 Polarity
You can change the polarity of the output
signals that are assigned to OUT0 to
OUT2 (regardless of what signal is
assigned to the output).
When FQ-SDU is connected, OUT0 to 2
will not appear.
Positive (Default)
Negative
System
---*
1
OUT1 Polarity
Positive (Default)
Negative
System
OUT2 Polarity
Positive (Default)
Negative
System
BUSY LED
You can change the BUSY indicator to a
RUN indicator.
BUSY (Default)
RUN
System
---*
1
Output control
You can select the data output method.
(Only when the FQ-SDU1
is con-
nected.)
None (Default)
Handshaking
Sync. Output
System
---*
1
Output period
Sets the period for outputting measure-
ment results. (Only when the FQ-SDU1
is connected.)
2.0 to 5,000.0 ms
10.0 ms (Default)
System
---*
1
GATE ON delay
Sets the time from when the result is out-
put to the parallel interface until the
GATE signal turns ON.
(Only when the FQ-SDU1
is con-
nected.)
1.0 to 1,000.0 ms
1.0 ms (Default)
System
---*
1
Output time
Sets the time to turn ON the GATE sig-
nal.
(Only when the FQ-SDU1
is con-
nected.)
1.0 to 1,000.0 ms
5.0 ms (Default)
System
---*
1
Timeout
Sets the timeout time for output control.
(Only when the FQ-SDU1
is con-
nected.)
0.5 to 120.0 s
10.0 s (Default)
System
---*
1
Number of delay
Set the number of times to ignore the
TRIG signal turning ON between when
the TRIG signal turns ON and the mea-
surement results are output.
(Only when the FQ-SDU1
is con-
nected.)
1 (Default) to 15
System
---*
1
ACK signal ON
period
Sets the output time of the normal execu-
tion completion signal for parallel com-
mands.
(Only when the FQ-SDU is connected.)
1.0 to 1,000.0 ms
5.0 ms (Default)
System
---*
1
Output polarity
Sets the ON/OFF polarity for all of the
output signals
(Only when the FQ-SDU is connected.)
Positive (Default)
Negative
System
---*
1
Inpu
t
Input mode
Specifies whether to use functions other
than scene switching for external parallel
commands.
Standard mode (Default)
Expanded mode
System
---*
1
Ou
tp
u
t da
ta
se
tt
ing
Noprot
ocol da
ta out
put Output data set
---
Data 0 to data 31
Scene
---*
1
[MENU]
Data settings
Sets data to output to selected data num-
ber.
Text strings for the filter items, position
compensation items, inspection items
and expression that are set
Scene
Multi-data
setting
Scene
Rename
Changes the name of the selected data
number.
The name can be changed to a name
with up to 15 alphanumeric characters.
Scene
Copy
Copies the contents registered in the
selected data number to another data
number.
Scene
Delete
Clears the content of the selected data
number.
Scene
Menu command
Description
Setting range
Data
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......