Logging Measurement Data and Image Data
398
FQ2-S/CH User’s Manual
File Format
Image data: Image data is saved in a special format for OMRON Sensors.
(The file name extension is IFZ.)
Measurement data: Measurement data is saved in the following CSV format.
*1:
The data and time are not recorded with the measurement data. Therefore, this is not the date that the measurement was executed. This
is the date that the PC Tool or the Touch Finder obtained the data from the Sensor.
*2:
Measurement ID is a value equal to the measurement count minus 1.
When launching the FQ2, the count starts from zero.
Item
Format
Description
1)
Date
*1
YYYY/MM/DD
This is the date that the measurement data was obtained
from the Sensor.
*1
2)
Time
*1
hh:mm:ss
This is the time that the measurement data was obtained
from the Sensor.
3)
Measurement ID
---
This is the measurement ID information.
*2
4)
Scene No.
---
Scene number
5)
Judge
---
Overall judgment
0: OK,
−
1: NG,
−
2: NC (not measured)
6)
Inspection item
region
I(inspection_item_number).(measure-
ment_item)(detection_point)
Example 1:
The correlation of the second detec-
tion point in a search for inspection
item number 0 would be given as fol-
lows: I0.CR2
Example 2:
The judgement result of OCR of
inspection item No. 0 would be given
as follows: I0.JG
The data selected for logging in the [Measurement data]
under [Log setting] is output.
If multiple results are detected, only the maximum number
of data items that is set in the [Measurement data] are out-
put.
7)
Expression
region
Zn.J**,Zn.D**
Example: The fourth registered
expression would be: Z0.J04,Z0.D04
(FQ2-S1)
The judgement result and calculation result of each expres-
sion are output.
** indicates 00 to 31.
Zn (expression variable):
Z0 for FQ2-S1/S2/S3, Z1 for FQ2-S4/CH.
1)
2)
3)
4)
5)
6)
7)
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......