Checking the Trend of Measurement Results with Graphs
FQ2-S/CH User’s Manual
361
6
Operatio
n
Arranging Histogram Display
The display range on the horizontal axis and the number of data on the vertical axis of the histogram can be
changed. To change the display range of the vertical axis, [Auto display] must be set to OFF.
• Disabling Automatic Adjustment of the Display Range (Default: ON)
1
Press [ ]
−
[Auto display] on the right of the histogram.
2
Press [OFF].
• Changing the Display Range of the Horizontal Axis
1
Press [ ]
−
[Display range] on the right of the histogram.
2
Select the maximum measurement value, the minimum measurement value, and the class.
• Changing the Number of Data on the Vertical Axis
1
Press [ ]
−
[Number of data] on the right of the histogram.
2
Select the maximum number of data to display.
• Histogram data is held until the power supply is turned OFF.
• You can select whether to display all data in the histogram or only data for which the overall judgment is NG. Log-
ging settings are applied to the histogram as well.
However, they are not applied to histograms displayed in Setup Mode.
Check recent measurement trends (recent results logging): p. 401
Note
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......