Shortening the Measurement Takt Time
FQ2-S/CH User’s Manual
343
5
Testin
g
a
nd Savin
g Se
ttin
gs
Increasing Image Input Speed
With the partial input function, it is possible to input only images that are in the region that is necessary for
measurements.
The image measurement region becomes smaller and therefore the image input time is shortened.
Consider the offset in the measurement object when you set the range.
The image in the input range will be displayed in the inspection item setting displays and measurement
displays.
• FQ2-S3/S4
[Image]
−
[Camera setup]
1
Press [ ]
−
[Partial input] on the right side of
the display.
2
Press [Y] and set the input range along the Y
axis by setting the Y coordinate of the partial in-
put start point and the Y coordinate of the par-
tial input end point.
3
Press [X] and set the input range along the X
axis by setting the X coordinate of the partial in-
put start point and the X coordinate of the par-
tial input end point.
4
Press [OK].
Partial input Y start line
Partial input Y end line
Y coordinate of the
partial input start point
Y coordinate of the
partial input end point
Partial input X
start line
X coordinate of the
partial input start point
X coordinate of the
partial input end point
Partial input X
end line
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......