Inspecting with the Edge Position Inspection Item
274
FQ2-S/CH User’s Manual
Step 3
Adjusting Judgment Parameters
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Edge Position]
−
[Settings] Tab Page
1
Press [Judgement].
2
Press the parameters and set the range that is to be
judged as OK.
The measurement value is displayed next to the param-
eter name. Continuous measurements will be performed
for the images that are displayed.
3
Press [OK] to enter the value.
Parameter
Setting
Description
Offset amount
Range:
−
99,999.9999 to 99,999.9999
Defaults: Lower:
−
1,640
Upper: 1,640
Sets the upper/lower limit range for the amount of posi-
tion deviation considered to be OK.
Position X
Range:
−
99,999.9999 to 99,999.9999
Defaults: Lower:
−
99,999.9999
Upper: 99,999.9999
Sets the upper/lower limit range for the amount of edge
position X considered to be OK.
Position Y
Range:
−
99,999.9999 to 99,999.9999
Defaults: Lower:
−
99,999.9999
Upper: 99,999.9999
Sets the upper/lower limit range for the amount of edge
position Y considered to be OK.
• You can change the output form for each measurement value to one of the following settings.
Press
[ ]
−
[Result type] on the right of the display.
Absolute value (Default): The measured coordinates are output as absolute values.
Relative value: The difference from the reference value is output.
Blue for OK. Red for NG.
Lower limit
Upper limit
You can change the parameters for judgement conditions on the
Display Settings Display. Press
[ ]
−
[Display setting] on the right
of the display to switch to the Display Settings Display.
Note
Note
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......