Inspecting with the Shape Search III Inspection Item
FQ2-S/CH User’s Manual
237
4
Setting Up Inspect
ions
Select the Results to Output
You can use multiple conditions to determine which results to output from all the objects detected with a
correlation at the candidate level or higher.
Only the results that meet all the specified conditions are output.
[Inspect]
−
[Inspection]
−
[Shape Search III]
−
[Modify]
−
[Details] Tab Page
−
[Meas. Parameter]
1
Press [Extraction condition] and adjust the candi-
date level so that only objects higher than a certain
correlation are detected.
2
Set the conditions for outputting the detected
objects.
(Extraction X/Y and Detection Count)
Extraction condition
Range
Description
Candidate level
0 to 100
Default: 50
Set the threshold to find Candidate.
Output only a value that is higher than [Candidate level].
Increase the value if Model search is unstable.
Extraction X
−
99999.9999 to 99999.9999
Defaults: Lower:
−
99,999.9999
Upper: 99,999.9999
Results are output only for objects with a measured X
coordinate that is within this range.
Extraction Y
−
99999.9999 to 99999.9999
Defaults: Lower:
−
99,999.9999
Upper: 99,999.9999
Results are output only for objects with a measured Y
coordinate that is within this range.
Detection count
1 to 32
Default: 1
Sets the maximum number of detection results to output.
The processing time changes if you change the candidate level.
Note
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......