Inspecting with the Shape Search III Inspection Item
232
FQ2-S/CH User’s Manual
Step 2
Teaching
Teaching means to store the region and partial image as reference data for the measurement.
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Shape Search III]
−
[Settings] Tab Page
The following data is stored as the measurement reference.
1
Press [Teach].
2
Place the object that is to be used as the measurement reference in front of the camera.
3
Move the rectangle to the location to be measured.
4
Press [OK].
5
Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has been completed.
6
Press [Back] to end teaching.
Item
Parameter
Description
Reference data
Model image
This is the partial image that is stored as the reference.
Reference position X
These are coordinates of the model image that are stored as refer-
ence.
Reference position Y
Reference angle
An angle when the model is registered.
Drag a corner to
size the rectangle.
Drag the rectangle
to move it.
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......