Reading with OCR
178
FQ2-S/CH User’s Manual
Measurement Data That Can Be Logged for OCR
Parameter
Setting
Description
Judgement
-2: No judgment (not measured)
0: Judgment is OK
-1: Judgment is NG
-11: Model does not match
-13: Measurement time out
-16: Measurement timeout error,
-17: Format not entered error
This is the judgment result.
Similarity
0 to 100
This is the lowest similarity of the read char-
acters.
Stability
0 to 100
This is the lowest stability of the read char-
acters.
Number of read characters on line 1
0 to 32
This is the number of characters that were
read on line 1.
Number of read characters on line 2
0 to 32
This is the number of characters that were
read on line 2.
Number of read characters on line 3
0 to 32
This is the number of characters that were
read on line 3.
Number of read characters on line 4
0 to 32
This is the number of characters that were
read on line 4.
Individual similarity
0 to 100
This is the similarity of read character N (N
= 0 to 127).
Individual stability
0 to 100
This is the stability of read character N (N =
0 to 127).
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......