Adjusting the Images That Were Taken
132
FQ2-S/CH User’s Manual
• Source Image
You can select the image to which to apply the results of position compensation processing.
You can set the image for position compensation for each position compensation item.
[Image]
−
[Image adjustment]
−
[Linear Corr.]
−
[Modify]
1
Press [ ]
−
[Source image] at the right of the screen.
2
For the source image, select [Camera] or [Prev. image].
• Position Interpolation
You can select the precision of position compensation.
If you select [Bilinear], the precision of position compensation will increase.
[Image]
−
[Image adjustment]
−
[Linear Corr.]
−
[Modify]
1
Press [ ]
−
[Interpolation] at the right of the screen.
2
Select [Bilinear] or [None] for position interpolation.
• Measurement Data That Can Be Used for External Outputs and Calculations
You can use the values below as measurement data for external output and calculations.
Parameter
Setting
Description
Source image
Camera
The results of processing the position compensation item is applied to
the image that is taken by the Camera.
This setting is used when filter items or other position compensation
items have been used specifically for the position compensation item.
Prev. (Default)
This setting is used when the processing results of the current position
item are to be applied to the image that results from previous filter items
or other position compensation items.
Parameter
Setting
Description
Interpolation
Bilinear
(Default)
Points are connected with lines to find approximations. This create
smoother images.
When [Bilinear] is selected, the processing time increases.
None
Position compensation is performed at the pixel level.
Expression
text string
Data name
Description
Data range
JG
Judgement
This is the judgement result.
-2: No judgement (not measured)
0: Judgement is OK
-1: Judgement is NG
Содержание FQ2-S/CH Series
Страница 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Страница 12: ...10 FQ2 S CH User s Manual MEMO...
Страница 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Страница 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Страница 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Страница 433: ...8 Troubleshooting Troubleshooting 8 1 Error Histories 432 8 2 Error Messages 434 8 3 Basic Troubleshooting 435...
Страница 581: ...Connecting a Previous Touch Finder FQ D30 D31 to the FQ2 S Sensor FQ2 S CH User s Manual 579 Appendices 9 MEMO...
Страница 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Страница 589: ......