23
F3SJ-A
User’s Manual
Chapter
2
Ba
si
c Sys
te
m
System Configuration and Functions
E
Basic System
Basic system indicates the F3SJ with its default factory settings.
The basic system provides basic safety light curtain functions. Most functions can be used without performing
additional configuration.
Wiring Diagrams
Wiring using manual reset mode, external device monitoring
1
2
3
4
5
6
8
1
2
3
4
5
6
7
8
K3
K2
K1
K2
+24V DC
0V
S1
S2
7
*1
*1
K1
*2
*2
*2
Open
S1
: External test switch
S2
: Interlock/lockout reset switch
K1,K2 : Relay or other device that controls
hazardous parts of the machine
K3
: Load or PLC, etc. (for monitoring)
Emitter
Receiver
(White) Interlock selection input
(Brown) 24V
(Green) Test input
(Yellow) Reset input
(Pink) Communication line (-)
(Blue) 0V
Shield
(Red)
(Brown) 24V
(Green) Safety output 1
(Pink) Communication line (-)
(Blue) 0V
Shield
(Red) External device monitoring input
(White) Safety output 2
(Grey)Communication line (+)
(Grey)Communication line (+)
*1 Use a switch for micro loads (Input specifications: 24V, 2.5mA)
*2 F3SJ operates even when K1 to K3 are not connected
(Yellow) Auxiliary output 1