103
F3SJ-A
User’s Manual
Ch
apt
e
r
5
Ma
int
en
anc
e Ch
eck
list
s
Checklists
E
6-Month Inspection
Items to inspect every 6 months or when machine settings are changed
The machine itself does not prevent the operation of safety functions such as stopping.
No modifications or connection changes have been made to the machine that may have an adverse
effect on the machine's control system.
The outputs of the F3SJ and the machine are properly wired.
The actual response time of the whole machine is equal to or less than the calculated value.
The total number of times that the control relays/contactors have switched is significantly lower than
their design lives.
The tightening screws for mounting brackets are not loose.
There is no disturbance light.