57
F3SG-SR
User’s Manual
Chapter
2
Auxiliary Output
System Operation and Functions
E
2-12. Auxiliary Output
Do not use the output signal of the auxiliary output for safety applications. Failure to do so may
result in serious injury when the F3SG-SR fails.
2-12-1. Overview
The Auxiliary Output is used to monitor the status of F3SG-SR. This output can be connected to a
device such as an indication lamp, PLC, etc.
Usage Example:
• Indicate that the F3SG-SR is in the MUTING or OVERRIDE state.
• Indicate that a machine is stopped. (Safety outputs are in the OFF state.)
Basic wiring diagram
The load current of the auxiliary output is 100 mA max.
F3SG-SRA
F3SG-SRB
+24 VDC
0V
PNP
0V
+24 VDC
NPN
Load
Load
24V/0V (Brown)
AUX (Red)
0V/24V (Blue)
24V/0V (Brown)
AUX (Red)
0V/24V (Blue)
F3SG-SR
receiver
F3SG-SR
receiver