![Omron F3SG-SR Series Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/omron/f3sg-sr-series/f3sg-sr-series_user-manual_744123068.webp)
40
Chapter
2
Self-Test
F3SG-SR
User’s Manual
System Operation and Functions
2-5. Self-Test
2-5-1. Overview
The F3SG-SR performs the Self-Test when power is turned ON (within 3 s) to check for errors.
Also, it regularly performs the Self-Test (within a response time) while operating.
This function cannot be cancelled.
If an error is found in the Self-Test, the F3SG-SR enters the LOCKOUT state, keeps the safety outputs
in the OFF state, and indicates the error at the same time.
2-5-1-1. Self-Test details
The Self-Test detects such error as described below.
Emitter
• Failure of emitter unit or circuit
• CPU failure
• Memory failure
• Failure of DIP Switch
Receiver
• Abnormal external power supply voltage
• Failure of internal power supply circuit
• Failure of receiver unit or detection circuit
• CPU failure
• Memory failure
• Failure of safety output circuit
• Disconnected or short-circuited cable
• Failure of DIP Switch
• Failure of End Cap
F3SG-SRA
F3SG-SRB
Subsequently performs periodic test
Power supply
ON
OFF
Self-Test
ON
OFF
3 s max.
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...