F3SG-SR
User’s Manual
Input/Output Circuit and Applications
6-2-1-9. Pre-Reset Mode with Reset Switch Connector
[Wiring Example]
• When using the Reset Switch Connector (F39-GCNY3), the following functions are not available.
- External Device Monitoring (EDM)
• When a functional earth is necessary, wire an earth cable according to the example in
Optical Synchronization and EDM Unused
5-4-4. Functional Earth Connection
for more information.
S2
S1
24 VDC
24 VDC
F39-JG C-L
F39-GCNY3
F39-JGR3K-D
XS5F-D421 80-F
F39-JG A-D
IN1
IN2
L1
Wiring for NPN *1
OSSD 1 (Blac
k)
OSSD 2 (White)
24V/0V (Bro
wn)
TEST (Blac
k)
Not used (White)
24V/0V (Bro
wn)
0V/24V (Blue)
0V/24V (Blue)
A
UX (Red)
Not used (Pink)
PRE-RESET (Gr
a
y)
RESET (Y
ello
w)
0V/24V (Blue)
RESET (White)
24V/0V (Bro
wn)
A
UX (Blac
k)
OPERA
TING
RANGE SELECT
INPUT (Y
ello
w) *2
Emitter
Receiver
Safety controller
*3 *4
*5
S3
Intelligent Tap
Needed
S1: Test switch
S2: Lockout/interlock reset switch
S3: Pre-reset switch
L1: Lamp
: Indicates a switch position
Function
Setting
DIP switch
SD Manager 3
EDM
N/A
Pre-Reset *6
Pre-Reset
[Pre-Reset] : Enable *6
Non-Muting system
Perform wiring according to the wiring diagram.
N/A
[Muting] : Disable *6
Operating Range Selection
Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to
24 VDC.
External Test used
Connect the TEST line of the emitter to 24V/0V via a test switch (NO contact). *7
N/A
[External test signal inversion] : Disable
Optical Synchronization
Do not connect the COM(+) and COM(-) lines of the of emitter and receiver with each other.
㻠
㻻㻺
㻡
㻻㻺
Timing chart
Pre-reset switch (S3)
Reset switch (S2)
OSSD
T1
T3
T2
Beam state: Unblocked
Blocked
Unexpected beam
block
T1: Minimum pressing time of pre-reset switch. Configurable from 100 to 500 ms in 100-ms increments.
T2: Maximum permissible time from input of PRE-RESET signal to input of RESET signal. Configurable from 1 to 60 s in 1-s increments.
T3: Minimum pressing time of reset switch. Configurable from 100 to 500 ms in 100-ms increments.
*1. Reverse the polarity of the power supply when using in the NPN system. Select a safety controller of
PNP or NPN type according to the system of your application.
*2. Connect the line to 0 VDC if Operating Range Selection is used in Short Mode.
*3. Refer to
6-3. Connectable Safety Control Units
for more information.
*4. The safety controller and the F3SG-SR must share the power supply or be connected to the common
terminal of the power supply.
*5. This is the case for a PELV circuit.
*6. Set the function with the DIP Switches on the Intelligent Tap or the SD Manager 3, restore the settings
to the F3SG-SR, and perform wiring according to the wiring diagram.
*7. This is the example for the PNP system to stop emission when the line is connected to 24 VDC and for
the NPN to stop emission when the line is connected to 0 VDC. If TEST switch is not needed, refer to
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...