Monitoring with SD Manager 3
Setting with SD Manager 3
E
4-4. Monitoring with SD Manager 3
4-4-1. Monitoring
Logging in is not needed to perform the monitoring functions described in this section.
4-4-1-1. Incident Light/Ambient Light
This function can be used only when the F3SG-SR is connected to the Intelligent Tap and a PC.
On the Top page, click the icon below.
The screen below is displayed.
No.
Function
Description
1
Select light level
monitoring function
Select incident light level or ambient light level to be monitored and chart or list view.
2
No. of beams to be
displayed
Select the number of F3SG-SR beams to be displayed.
3
Show/hide held peak and
bottom hold
Shows the maximum and minimum values of a selected light level by light blue and pink
lines, respectively when [Show] is selected.
4
Select unit of vertical axis
Switch the unit of the vertical axis on the chart between Percent and Level. When [Percent]
is selected, the light level is shown in percentage based on the ON threshold value as
100%. When [Level] is selected, the light level is converted to voltage.
5
ON/OFF threshold values
Shows the ON and OFF threshold values of the F3SG-SR.
This information is only shown when the [Level] view is selected for the unit of vertical axis.
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...