130
Chapter
3
List of Functions Configurable by Intelligent Tap and Initial Setup Method
F3SG-SR
User’s Manual
Setting with Intelligent Tap
3-1. List of Functions Configurable by Intelligent Tap
and Initial Setup Method
3-1-1. Functions Configurable by Intelligent Tap
The following functions are configurable by the DIP Switch on the Intelligent Tap (F39-SGIT-IL3).
No password is required for configuring the functions by the DIP Switch on the Intelligent Tap. Make sure the
Responsible Person keeps the Intelligent Tap properly.
3-1-2. Initial Setup Method after Purchase
When connecting the Intelligent Tap to the F3SG-SR for the first time after purchase, you need to
make the following settings.
1.
Connect the Intelligent Tap to the F3SG-SR. The factory default setting of the DIP Switch Position 1 is
ON. If the Position 1 is set at OFF, switch the position to ON.
2.
Turn the power on. Then the Intelligent Tap performs the Backup automatically and restarts itself.
3.
If the DIP Switch Position 1 is set at ON (Lock), the F3SG-SR performs its normal operation.
4.
Operate according to the usage below.
• Setting with DIP Switch
Turn the power off and operate referring to the following chapter(s).
3-5. DIP Switch on Intelligent Tap and 3-6-3. Performing Restoration
• Setting with SD Manager 3
Connect a USB-C
TM
cable to the Intelligent Tap and operate referring to the following chapter(s).
Chapter 4 Setting with SD Manager 3
• Setting not needed
Use the devices as they are.
- When the DIP Switch Position 1 is set at OFF (Unlock) in the step 1 and 2, the Intelligent Tap and the F3SG-SR are
waiting for the Backup operation (or waiting for Push Switch operation). In this case, turn the power off, then switch the
DIP Switch Position to ON (Lock) and turn the power on again. After this, the F3SG-SR performs its normal operation.
- If you write settings with SD Manager 3 to the Intelligent Tap alone before you connect the Intelligent Tap to the F3SG-
SR for the first time after purchase, the Backup is not started automatically. Operate according to the Backup
procedure. For more information on the Backup procedure, refer to
Function
Page
Interlock
Pre-Reset
External Device Monitoring (EDM)
Fixed Blanking
Floating Blanking
Operating Range Selection
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...