102
Chapter
2
Reduced Resolution
F3SG-SR
User’s Manual
System Operation and Functions
Detection capability
Detection capability for the F3SG-SR differs based on the number of floating beams as shown below.
LED indicator status
When the Reduced Resolution is being enabled, the CFG indicator turns on.
Refer to 2-1. Combination of Functions for more information on the use in conjunction with other functions.
2-17-2. Factory Default Setting
Reduced Resolution is disabled.
2-17-3. Setting with Intelligent Tap
The user cannot make any changes to the settings of this function by DIP Switch on the Intelligent Tap.
Model
Number of blocked
beams configured
Detection capability
Number of blocked
beams to turn safety
outputs OFF
Maximum diameter
that does not turn off
the safety outputs in
the detection zone
F3SG-
SR
-14
-
14 mm
1 beam
-
1 beam
24 mm
2 beams
6 mm
2 beams
34 mm
3 beams
16 mm
3 beams
44 mm
4 beams
26 mm
F3SG-
SR
-25
-
25 mm
1 beam
-
1 beam
45 mm
2 beams
15 mm
2 beams
65 mm
3 beams
35 mm
3 beams
85 mm
4 beams
55mm
F3SG-
SR
-45
-
45 mm
1 beam
-
1 beam
85 mm
2 beams
35 mm
2 beams
125 mm
3 beams
75 mm
3 beams
165 mm
4 beams
115 mm
F3SG-
SR
-85
-
85 mm
1 beam
-
1 beam
165 mm
2 beams
75 mm
2 beams
245 mm
3 beams
155 mm
3 beams
325 mm
4 beams
235 mm
Содержание F3SG-SR Series
Страница 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Страница 18: ...xvi Introduction F3SG SR User s Manual...
Страница 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Страница 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Страница 360: ...332 Chapter 6 Connectable Safety Control Units F3SG SR User s Manual Input Output Circuit and Applications...
Страница 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Страница 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...