89
F3SG-SR
User’s Manual
Chapter
2
Override
System Operation and Functions
E
2-14-5. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Setting the override time limit to infinite may cause a failure of disabling the OVERRIDE state when there is a failure of
the override input signal. Conduct risk assessment analysis thoroughly before enabling this setting.
Function
Initial value
Configurable value or numerical range
Override
Enable
Enable/Disable
Override input time limit
1 s
0.2 to 5 s in 0.1-s increments
Override time limit
600 s
1 to 600 s in 1-s increments, or infinite