Input/Output Circuit and Applications
5-2-2-3. Standard Muting Mode/Exit-Only Muting Mode with two Muting
Sensors using PNP Outputs
The following is the example of External Device Monitoring disabled, Auto Reset mode, PNP output
and External Test in 24 V Active.
[DIP Switch settings] *5
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
[Wiring Example]
Function
DIP-SW1
DIP-SW2
Receiver
EDM Disabled (factory default setting)
Auto Reset (factory default setting)
PNP (factory default setting)
Emitter
External Test: 24 V Active (factory default setting)
㻞
㻻㻺
㻞
㻻㻺
㻟
㻻㻺
㻟
㻻㻺
㻠
㻻㻺
㻠
㻻㻺
㻣
㻻㻺
㻣
㻻㻺
㻠
㻻㻺
OSSD
1 : Black
OSSD
2 : White
24
VDC : Brown
Not used : Yellow
TEST
:
Black
Not used : White
24
VDC : Brown
0
VDC : Blue
Receiver
Emitter
0
VDC : Blue
AUX : Red
MUTE B
: Pink
MUTE A
: Gray
RESET : Yello
w *1
S1: Test Switch (Connect the line to 0 V if this switch is not required)
S2: Lockout/Interlock Reset Switch,Override Switch or Override Cancel Switch
A1, B1: Muting sensor
S1
S2
*2
Muting
Sensor
(PNP
output)
Reflector
F39-JG
A-L
F39-JG
A-D
A1
B1
Power Supply
+24 VDC
0 VDC
Safety
Controller *3 *4
IN1
IN2
Unblocked
Blocked
MUTE A
MUTE B
OSSD
Test Switch (S1)
Beam state
PLC *6
IN
*1. Also used as Override input line.
*2. Make sure to connect an override cancel switch to the
Reset line when using the override function. Otherwise
the override state may not be released by the override
cancel switch, resulting in serious injury.
*3. Refer to
5-4. Connectable Safety Control Units
more information.
*4. The safety controller and the F3SG-R must share the
power supply or be connected to the common terminal
of the power supply.
*5. The functions are configurable with DIP Switch. Refer
to
Chapter 3 Setting with DIP Switch
information on setting the functions by the DIP Switch.
*6. When connecting to the PLC, the output mode must be
changed with the Configuration Tool according to your
application.
Содержание F3SG-RA
Страница 1: ...F3SG R Series Safety Light Curtain User s Manual Cat No Z352 E1 08 http www ia omron com f3sg r...
Страница 16: ...xiv Introduction F3SG R User s Manual...
Страница 24: ...xxii Introduction F3SG R User s Manual...
Страница 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Страница 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Страница 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Страница 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...