182
Chapter
4
Wiring
F3SG-R
User’s Manual
Wiring/Installation
4-5-4-4. Reduced Wiring Connector System
Reduced wiring can be achieved by using a Y-Joint Plug/Socket Connector (F39-GCNY1, sold separately).
When using the reduced wiring connector system, the Operating Range Selection is fixed to Long Mode.
Y-Joint Plug/Socket Connector (F39-GCNY1, sold separately)
<Internal wiring diagram>
Wrong wiring causes the F3SG-RE to go to the Lockout state due to Operating Range Selection Setting error.
Model
L (m)
F39-GCNY1
0.5
CN1
CN2
4.6 dia.
17.7
45.5
M12 x 1
40.7
35.0
15.0
500
To receiver
To control
panel side
To emitter
M12 IP67 connector, 4-wire
M12 IP67 connector, 4-wire
Insulated vinyl round cable dia. 6
M12 IP67 connector, 4-wire
Plug marked with ● (blue circle): Connect to control panel side
Socket marked with ○ (open circle): Connect to emitter
(Unit: mm)
Material: PBT (Main body)
1
2
3
4
Female
Male
Connected to Single-Ended Cable or
Double-Ended cable
Connected to Power Cable or
Double-Ended Cable of F3SG-RE Emitter
Connected to Power Cable or
Double-Ended Cable of F3SG-RE Receiver
3
2
1
4
Female
4
1
2
3
3
2
1
4
㻝
+24 VDC
OSSD 1
OSSD 2
0 VDC
㻞
㻟
㻠
Brown
White
Blue
Black
㻝
+24 VDC
Not used
Operating Range Select Input
0 VDC
㻞
㻟
㻠
Brown
White
Blue
Black
Содержание F3SG-RA
Страница 1: ...F3SG R Series Safety Light Curtain User s Manual Cat No Z352 E1 08 http www ia omron com f3sg r...
Страница 16: ...xiv Introduction F3SG R User s Manual...
Страница 24: ...xxii Introduction F3SG R User s Manual...
Страница 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Страница 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Страница 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Страница 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...