2-22. Designated Beam Output
2-22-1. Overview
This function allows information on unblocked/blocked states of a given beam to be output.
Example:
• To turn a Lamp ON when a specified beam of F3SG-RA is blocked
• To output, from the auxiliary output, a signal of information on a specified beam being unblocked
If one or more specified beams are blocked or unblocked, the information on the beam state can be
provided as an auxiliary output or indication of Lamp.
Operation Example
Designated beam state: Dark-ON
The Designated Beam Output is not available for the F3SG-RE.
2-22-2. Factory Default Setting
The factory default setting is Designated Beam Output as Disable.
F3SG-RA Series
X
F3SG-RE Series
Safety output ON
Safety output OFF
Safety output OFF
Designated beam output OFF
Designated beam output ON
Designated beam output OFF
Figure 1
Figure 2
Figure 3
Designated
beam
Designated
beam
Beam state
Beam state
(Designated beam)
Unblocked
Blocked
(Other than designated beam)
Designated beam output
ON
OFF
Unblocked
Blocked
OSSD
ON
OFF
Содержание F3SG-RA
Страница 1: ...F3SG R Series Safety Light Curtain User s Manual Cat No Z352 E1 08 http www ia omron com f3sg r...
Страница 16: ...xiv Introduction F3SG R User s Manual...
Страница 24: ...xxii Introduction F3SG R User s Manual...
Страница 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Страница 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Страница 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Страница 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...