77
F3SG-4RA-25-02TS
User’s Manual
Chapter
4
Wiring
Wiring/Installation
E
Reduced Wiring Connector (F39-CN5, sold separately)
<Internal wiring diagram>
4-5-3-6. Extending Cable Length with Commercially Available Cable
When you need to use a cable that is not specified by OMRON, use a cable that satisfies the following
specifications.
1. Emitter: 5-wire Receiver: 8-wire
2. 0.3 mm
2
or larger, conductor resistance 0.058 ohms/m max.
3. PC COM (+) and PC COM (-) lines, and 24 VDC and 0 VDC lines must be used as twisted-pair
lines.
Do not use cables in the same conduit as high voltage or electric power lines.
24.7
12
13.6
13.6 Φ8 (SPOT FACING 2)
Φ4.5
(52)
32.1
10
17.7
18
[Unit: mm]
1
2
3
4
5
6
7
8
1
Female
7
8
2
3
4
5
6
1
Female
7
8
2
3
4
5
6
Male
2
3
8
1
7
6
5
4
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
White
Brown
Black
Yellow
Gray
Pink
Blue
Red
White
Brown
Black
Yellow
Gray
Pink
Blue
Red
White
Brown
Black
Yellow
Gray
Pink
Blue
Red
OSSD 2
OSSD 1
Not used
PC COM (+)
PC COM (-)
0 VDC
TEST
+24 VDC
Connected to Power Cable or
Double-Ended Cable of F3SG-R Emitter
Connected to Power Cable or
Double-Ended Cable of F3SG-R Receiver
Содержание F3SG-R Series
Страница 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Страница 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Страница 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Страница 106: ...86 Chapter 5 Connectable Safety Control Units F3SG 4RA 25 02TS User s Manual Input Output Circuit and Applications...
Страница 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...