47
F3SG-SR/PG
User’s Manual
Chapter
2
Combina
tion of
F
unct
ions
System Operation and Functions
E
The F3SG-SR/PG must be installed, configured, and incorporated into a machine control system
by a sufficiently trained and qualified person. An unqualified person may not be able to perform
these operations properly, which may cause a person to go undetected, resulting in serious injury.
Make sure the Responsible Person test the operation of the F3SG-SR/PG after setting with the SD
Manager 3 to verify that the F3SG-SR/PG operates as intended. Make sure to stop the machine until
the test is complete. Unintended settings may cause a person to go undetected, resulting in serious
injury.
2-1. Combination of Functions
Possible combinations of the F3SG-SR/PG functions are shown in the table below. The combinations in the
table are available under certain conditions. The other functions can be combined without any limitations.
The functions listed in the table below are not available for the F3SG-RE.
Refer to
2-19. Setting Zone Adjacency Conditions
for further information.
YES: Combination available
YES-C: Combination available by setting with SD Manager 3.
NO: Combination unavailable
*1. This combination requires that the Floating Blanking zone covers the full detection zone and that the Muting/Override function also
covers the full detection zone.
Fixed
Blanking
*6
Floating
Blanking
*6
Reduced
Resolution
*6
Muting/
Override
Pre-
Reset
Warning
Zone
*6
EDM
Interlock
Input
signal
linkage of
ABI
Teach-in
input
Push-SW or
external
wiring
*6
PSDI
*6
Fixed Blanking
*6
-
YES-C
*2
NO
YES
NO
YES-C
YES
YES
YES-C
YES-C
YES-C
Floating Blanking
*6
YES-C
*2
-
NO
YES
*1
NO
YES-C
YES
YES
YES-C
*3
YES-C
*3
YES-C
*3
Reduced Resolution
*6
NO
NO
-
NO
YES-C
NO
YES-C
YES-C
YES-C
YES-C
YES-C
Muting/Override
YES
YES
*1
NO
-
NO
YES-C
YES
YES
YES
NO
NO
Pre-Reset
NO
NO
YES-C
NO
-
YES-C
YES
NO
NO
NO
NO
Warning Zone
*6
YES-C
YES-C
NO
YES-C
YES-C
-
YES-C
YES-C
YES-C
YES-C
YES-C
EDM
YES
YES
YES-C
YES
YES
YES-C
-
YES
YES-C
YES-C
YES-C
Interlock
YES
YES
YES-C
YES
NO
YES-C
YES
-
YES-C
YES-C
NO
Input signal linkage
of ABI
*4
YES-C
YES-C
*3
YES-C
NO
NO
YES-C
YES-C
YES-C
-
NO
NO
Teach-in input
Push-SW or external
wiring
*5*6
YES-C
YES-C
*3
YES-C
NO
NO
YES-C
YES-C
YES-C
NO
-
NO
PSDI
*6
YES-C
YES-C
*3
YES-C
NO
NO
YES-C
YES-C
NO
NO
NO
-
Содержание F3SG-PG Series
Страница 18: ...xvi Introduction F3SG SR PG User s Manual...
Страница 30: ...xxviii Introduction F3SG SR PG User s Manual...
Страница 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Страница 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Страница 226: ...196 Chapter 3 Intelligent Tap Application Example F3SG SR PG User s Manual Setting with Intelligent Tap...
Страница 430: ...400 Chapter 6 Connectable Safety Control Units F3SG SR PG User s Manual Input Output Circuit and Applications...
Страница 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...