422
Chapter
8
Troub
le
sho
oting
F3SG-SR/PG
User’s Manual
Appendix
8-1-3-5. PSDI Sequence Error Indication
The following table is applied only when the PSDI function is being enabled.
Notations
...Single Break
...Double Break
...Common
SEQ indicator
Error
condition
Cause and measures
Blinking: Once
Power supply may have been turned ON with PSDI input being OFF.
Check the condition of the light curtains and PSDI input wiring.
Power supply may have been turned ON with the light curtain blocked.
Check the condition of the light curtains and PSDI input wiring.
Power supply may have been turned ON with RESET input being OFF.
Check the condition of the light curtains and RESET input wiring.
PSDI input may have been turned OFF before RESET input was turned OFF.
Check the PSDI input wiring.
The light curtain may have been blocked before RESET input was turned ON.
Check the condition of the light curtains and RESET input wiring.
The PSDI input may have turned OFF while the RESET input is OFF.
Check the condition of the light curtains and PSDI input wiring.
The light curtain may have been blocked before RESET input was turned ON.
Check the condition of the light curtains and RESET input wiring.
Blinking: Twice
After RESET input , the light curtain may not be blocked longer than T2 (minimum
break time) and the PSDI input may have turned OFF.
Check the condition of the light curtains and RESET input wiring.
The PSDI input may have turned OFF with the light curtain blocked.
Check the condition of the light curtains and PSDI input wiring.
PSDI input may have turned OFF before the light curtain blocked twice.
Check the condition of the light curtains and PSDI input wiring.
Blinking: Three times
The light curtain was blocked before the PSDI input turned OFF.
Check the condition of the light curtains and PSDI input wiring.
The light curtain was blocked while the PSDI input turned OFF.
Check the condition of the light curtains and PSDI input wiring.
Blinking: Four times
PSDI input may have turned OFF during the period from when the PSDI state is
cancelled until the light curtain blocked.
Check the condition of the light curtains and PSDI input wiring.
The PSDI input may have turned OFF with the light curtain blocked.
Check the condition of the light curtains and PSDI input wiring.
T4 (waiting time for break end of one time) after the PSDI state is released until the
break is released might have exceeded 30 s.
Check the condition of the light curtains and PSDI input wiring.
T6 (muting end waiting time) after the PSDI state is released until the break is
released might have exceeded 30 s.
Check the condition of the light curtains and PSDI input wiring.
The PSDI input may have turned OFF again before the light curtain blocked.
Check the condition of the light curtains and PSDI input wiring.
After PSDI is input, if the light curtain is blocked twice, the time elapsing until the
second blocking ends must be within T6 (30 s). So, T6 (muting end waiting time)
might have elapsed.
Check the condition of the light curtains and PSDI input wiring.
PSDI input may have turned OFF before the light curtain blocked again.
Check the light curtain status and PSDI input wiring.
Содержание F3SG-PG Series
Страница 18: ...xvi Introduction F3SG SR PG User s Manual...
Страница 30: ...xxviii Introduction F3SG SR PG User s Manual...
Страница 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Страница 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Страница 226: ...196 Chapter 3 Intelligent Tap Application Example F3SG SR PG User s Manual Setting with Intelligent Tap...
Страница 430: ...400 Chapter 6 Connectable Safety Control Units F3SG SR PG User s Manual Input Output Circuit and Applications...
Страница 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...