391
F3SG-SR/PG
User’s Manual
Chapter
6
Wiring Exa
m
p
le
s
(f
or F3
SG-SR/PG)
Input/Output Circuit and Applications
E
6-2-1-8. Pre-Reset Mode with EDM Unused
[Wiring Example (F3SG-SR and F3SG-PGA-A/-L*8)]
When a functional earth is necessary, wire an earth cable according to the example in
6-2-1-1. Auto Reset Mode with Optical
Synchronization and EDM Unused
. Also refer to
5-4-4. Functional Earth Connection
F3SG-SRA
F3SG-PGA-A/-L
F3SG-SRB
F3SG-PGA-C
*8
24
V
DC
W
iring for
N
P
N
*1
*6
24
V
DC
I
N
PLC *3
I
N
1
Safety controller
*4 *5
I
N
2
S1
Recei
v
er
Emitter
OSSD 1 (Black)
OSSD 2 (
W
hite)
24
V
/0
V
(Bro
w
n)
OPERATI
N
G RA
N
GE
SELECT I
N
PUT (Yello
w
) *2
TEST (Black)
N
ot
u
sed (
W
hite)
24
V
/0
V
(Bro
w
n)
0
V
/24
V
(Bl
u
e)
0
V
/24
V
(Bl
u
e)
AUX (Red)
N
ot
u
sed (Pink)
PRE-RESET (Gray)
RESET/EDM
(Y
ello
w
) *3
S3
S2
F39-JGR3K-L
F39-JG
A-L
F39-JGR3K-D
F39-JG
A-D
*1. Reverse the polarity of the power supply when using in the NPN system. Select a PLC and a safety controller of PNP or NPN type according to
the system of your application.
*2. Connect the line to 0 VDC if F3SG-SR or F3SG-PGA-L is used in Short Mode. F3SG-PGA-A/-C does not support the Operating Range
Selection function.
*3. When connecting to the PLC, the output mode must be changed with the SD Manager 3 according to your application. Refer to
for more information on setting this function by the SD Manager 3.
*4. Refer to
6-3. Connectable Safety Control Units
for more information.
*5. The safety controller and the F3SG-SR/PG must share the power supply or be connected to the common terminal of the power supply.
*6 This is the case for a PELV circuit.
*7 Set the function with the DIP Switches on the Intelligent Tap or the SD Manager 3, restore the settings to the F3SG-SR/PG, and perform wiring
according to the wiring diagram.
*8. To use F3SG-PGA-C, wire the receiver side of the emitter/receiver of F3SG-PGA-C as shown in the above figure. Wiring of the emitter side is not needed.
*9. F3SG-PGA-C does not support the External Test function.
Timing chart
Pre-reset s
w
itch (S3)
Reset s
w
itch (S2)
OSSD
T1
T3
T2
Beam state: Un
b
locked
Blocked
Unexpected
b
eam
b
lock
T1: Minim
u
m pressing time of pre-reset s
w
itch. Config
u
ra
b
le from 100 to 500 ms in 100-ms increments.
T2: Maxim
u
m permissi
b
le time from inp
u
t of PRE-RESET signal to inp
u
t of RESET signal. Config
u
ra
b
le from 1 to 60 s in 1-s increments.
T3: Minim
u
m pressing time of reset s
w
itch. Config
u
ra
b
le from 100 to 500 ms in 100-ms increments.
S1: Test s
w
itch
S2: Locko
u
t/interlock reset s
w
itch
S3: Pre-reset s
w
itch
PLC: Programma
b
le logic controller (Used for monitoring only.
N
OT related to safety system.)
: Indicates a switch position.
Function
Setting
DIP switch
SD Manager 3
EDM *7
EDM Disabled (factory default setting)
EDM Disabled
[External device monitoring] : Disable
Pre-Reset *7
Pre-Reset
[Pre-Reset] : Enable
Operating Range Selection
Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC.
Non-Muting system
Perform wiring according to the wiring diagram.
External Test used *9
Connect the TEST line of the emitter to 24V/0V of the emitter via a test switch (NO contact).
Optical Synchronization
Do not connect the COM(+) and COM(-) lines of the of emitter and receiver with each other.
㻟
㻻㻺
㻠
㻻㻺
㻡
㻻㻺
Intelligent Tap
Needed
Содержание F3SG-PG Series
Страница 18: ...xvi Introduction F3SG SR PG User s Manual...
Страница 30: ...xxviii Introduction F3SG SR PG User s Manual...
Страница 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Страница 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Страница 226: ...196 Chapter 3 Intelligent Tap Application Example F3SG SR PG User s Manual Setting with Intelligent Tap...
Страница 430: ...400 Chapter 6 Connectable Safety Control Units F3SG SR PG User s Manual Input Output Circuit and Applications...
Страница 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...