385
F3SG-SR/PG
User’s Manual
Chapter
6
Wiring Exa
m
p
le
s
(f
or F3
SG-SR/PG)
Input/Output Circuit and Applications
E
6-2-1-2. Auto Reset Mode with Wired Synchronization and EDM Unused
[Wiring Example (F3SG-SR and F3SG-PGA-A/-L)]
• When a functional earth is necessary, wire an earth cable according to the example in
Optical Synchronization and EDM Unused
. Also refer to
5-4-4. Functional Earth Connection
F3SG-SRA
F3SG-PGA-A/-L
F3SG-SRB
F3SG-PGA-C
Beam state: Unblocked
Blocked
OSSD
OSSD (Black)
OSSD (White)
24V/0V (Brown)
COM(-) (Yellow)
TEST (Black) *2
COM(+) (White)
24V/0V (Brown)
0V/24V (Blue)
0V/24V (Blue)
AUX (Red)
COM(-) (Pink)
COM(+) (Gray)
F39-JG
C-L
F39-JG
C-D
Timing chart
24 VDC
Wiring for NPN *1
24 VDC
IN1
IN2
RESET/EDM
(Yellow) *3
*6
Receiver
Emitter
Safety controller
*4 *5
*1. Reverse the polarity of the power supply when using in the NPN system. Select a safety controller
of PNP or NPN type according to the system of your application.
for more information if External Test is used.
*3. Connect the line to 24V/0V (brown) of the receiver via a lockout reset switch (NC contact) if
Lockout Reset is used.
6-3. Connectable Safety Control Units
for moreinformation.*6
*5. The safety controller and the F3SG-SR/PG must share the power supply or be connected to the
common terminal of the power supply.
*6. This is the case for a PELV circuit.
Function
Setting
EDM
EDM Disabled (factory default setting)
Interlock
Auto Reset (factory default setting)
Operating Range Selection
Long (factory default setting)
Non-Muting system
Perform wiring according to the wiring diagram.
External Test not used
Connect the TEST line of the emitter to 0V/24V of the emitter.
Optical Synchronization
Connect the COM(+) and COM(-) line of the emitter and receiver with each other.
Intelligent Tap
Not Needed
Содержание F3SG-PG Series
Страница 18: ...xvi Introduction F3SG SR PG User s Manual...
Страница 30: ...xxviii Introduction F3SG SR PG User s Manual...
Страница 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Страница 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Страница 226: ...196 Chapter 3 Intelligent Tap Application Example F3SG SR PG User s Manual Setting with Intelligent Tap...
Страница 430: ...400 Chapter 6 Connectable Safety Control Units F3SG SR PG User s Manual Input Output Circuit and Applications...
Страница 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...