373
F3SG-SR/PG
User’s Manual
Ch
apt
e
r
5
Wir
ing
Wiring and Installation
E
5-4-3-14. Wiring of IP69K Model
No dedicated cable is used for F3SG-SR-K. To extend the cable, use a cable satisfying the
specification below.
1. Emitter: 5-wire, receiver: 8-wire
2. 0.3mm
2
or larger, conductor resistance 0.058 ohms/m max.
Do not use cables in the same conduit as high voltage or electric power lines.
<Emitter>
<Receiver>
15,000
(Unit: mm)
Brown
Black
Blue
White
Yellow
24V/0V
TEST
0V/24V
COM(+)
OPERATING RANGE SELECT INPUT/COM(-)
Oil-resistant PVC-insulated round cable, dia. 6
minimum bending radius R5, 5-wire
(Cross section of conductor: 0.3 mm
2
/insulator diameter: dia. 1.1 mm/AWG24)
(Unit: mm)
15,000
Brown
24V/0V
Blue
0V/24V
Black
OSSD 1
White
OSSD 2
Yellow
RESET/EDM
Red
AUX
Gray
MUTE A/PRE-RESET/PSDI/COM(+)
Pink
MUTE B/COM(-)
Oil-resistant PVC-insulated round cable, dia. 6
minimum bending radius R5, 8-wire
(Cross section of conductor: 0.3 mm
2
/insulator diameter: dia. 1.1 mm/AWG24)
Содержание F3SG-PG Series
Страница 18: ...xvi Introduction F3SG SR PG User s Manual...
Страница 30: ...xxviii Introduction F3SG SR PG User s Manual...
Страница 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Страница 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Страница 226: ...196 Chapter 3 Intelligent Tap Application Example F3SG SR PG User s Manual Setting with Intelligent Tap...
Страница 430: ...400 Chapter 6 Connectable Safety Control Units F3SG SR PG User s Manual Input Output Circuit and Applications...
Страница 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...