6 Programless Communications
E5@C Digital Temperature Controllers Communications Manual (H175)
6-2 E5
C Set
u
p
6
6-
2-9 Cop
ying Para
meter Settings
(5)
copy
and execute the copy operation.
If you select
all
, the parameters settings will be copied to all of the slaves. If you select a
number, the parameters settings will be copied to the slave with the selected
communications unit number.
Note: 1 You cannot cancel copying once the copying operation has been started. Even if you change the set
value during the copying operation, the current processing will be continued.
2 If copying fails, the copying operation will be aborted and the parameter settings will not be copied to the
remaining slaves.
For a Mitsubishi PLC, the ERR. indicator on the Serial Communications Module will light during the
copying process, but this does not indicate an error. The ERR. indicator will go out when the PLC is
restarted.
Refer to
for specific copying procedures.
Troubleshooting
Set value
Description
off
(
e0
**)
Copying is not in progress. The display will automatically return to
off
when the
copy operation is completed normally.
If the copy operation fails,
E
** will be displayed instead of
off
. The asterisks will
be replaced with the communications unit number of the slave where copying
failed. This value will be maintained until the copy operation is completed normally
or until you return to the operation level.
Example: If copying failed at the slave with communications unit number 2,
e002
will be displayed.
all
The parameter settings are copied to the slaves starting with the slave with
communications unit number 1 and continuing on to the slave with the
communications unit number that is set in the Highest Communications Unit No.
parameter. When copying is started, the PV display on the slave will change to
copy
. The copying operation is completed when all of the slaves are reset.
1 to 31
The parameter settings are copied to the slave with the specified communications
unit number, and then all of the slaves are automatically reset.
Check the slave where the error occurred.
YES
NO
NO
NO
copy
displayed?
Execute the copy again from the master using
all
.
Is the wiring incorrect?
YES
NO
YES
YES
YES
Copying is not possible. Copy the parameter
settings to the remaining slaves by specifying
their communications unit numbers individually.
Is the model number of the slave different
from the master?
Turn OFF the power supply and correct the wiring.
a) If there are a lot of slaves to which the settings
were not copied, set the Protocol Setting
parameter to
cwf
and the Communications
Baud Rate parameter to 9.6, return to the
operation level. Set the communications baud
rate of the master to 9.6, return to the operation
level, and then execute the copy again using
all
.
b) If there are only a few slaves to which the
settings were not copied, copy the parameter
settings to the remaining slaves (i.e., those for
which
copy
is not displayed) by specifying their
communications unit numbers individually.
Is the Protocol Setting parameter set to something
other than
cwf
?
Are the communications unit numbers incorrect?
Is the communications baud rate set to something other than 9.6?
The communications unit number of the
slave where the error occurred is also
being used by a downstream slave.
Correct the set values, return to the operation
level, and then execute the copy again from the
master using
all
.
Содержание E5AC
Страница 2: ......
Страница 16: ...Revision History 14 E5 C Digital Temperature Controllers Communications Manual H175...
Страница 22: ...20 E5 C Digital Temperature Controllers Communications Manual H175...
Страница 54: ...2 CompoWay F Communications Procedures 2 22 E5 C Digital Temperature Controllers Communications Manual H175...
Страница 96: ...4 Modbus Communications Procedure 4 16 E5 C Digital Temperature Controllers Communications Manual H175...
Страница 114: ...5 Communications Data for Modbus 5 18 E5 C Digital Temperature Controllers Communications Manual H175...
Страница 206: ...6 Programless Communications 6 92 E5 C Digital Temperature Controllers Communications Manual H175...
Страница 214: ...7 Component Communications 7 8 E5 C Digital Temperature Controllers Communications Manual H175...
Страница 219: ...I 1 E5 C Digital Temperature Controllers Communications Manual H175 I Index...
Страница 222: ...I 4 E5 C Digital Temperature Controllers Communications Manual H175...
Страница 223: ......