Specifications
Input Type
Set the code according to the following table. Default is “2: K1 ther-
mocouple.”
Platinum Resistance Thermometer
Set
Input type
Set
value
Input type
0
JPt100
–199.9 to 650.0 (
°
C)
/–199.9 to 999.9 (
°
F)
Platinum
resistance
th
t
1
Pt100
–199.9 to 650.0 (
°
C)
/–199.9 to 999.9 (
°
F)
thermometer
2
K1
–200 to 1,300 (
°
C)
/–300 to 2,300 (
°
F)
Thermocouple
3
K2
0.0 to 500.0 (
°
C)
/0.0 to 900.0 (
°
F)
4
J1
–100 to 850 (
°
C)
/–100 to 1,500 (
°
F)
5
J2
0.0 to 400.0 (
°
C)
/0.0 to 750.0 (
°
F)
6
T
–199.9 to 400.0 (
°
C)
/–199.9 to 700.0 (
°
F)
7
E
0 to 600 (
°
C)
/0 to 1,100 (
°
F)
8
L1
–100 to 850 (
°
C)
/–100 to 1,500 (
°
F)
9
L2
0.0 to 400.0 (
°
C)
/0.0 to 750.0 (
°
F)
10
U
–199.9 to 400.0 (
°
C)
/–199.9 to 700.0 (
°
F)
11
N
–200 to 1,300 (
°
C)
/–300 to 2,300 (
°
F)
12
R
0 to 1,700 (
°
C)
/0 to 3,000 (
°
F)
13
S
0 to 1,700 (
°
C)
/0 to 3,000 (
°
F)
14
B
100 to 1,800 (
°
C)
/300 to 3,200 (
°
F)
15
W
0 to 2,300 (
°
C)
/0 to 4,100 (
°
F)
16
PL
II
0 to 1,300 (
°
C)
/0 to 2,300 (
°
F)
17
4 to 20 mA
Current input
18
0 to 20 mA
19
1 to 5 V
Voltage input
20
0 to 5 V
21
0 to 10 V
Output Assignments
Thirteen output functions are available. Allocate these functions to
the control outputs 1 and 2 and auxiliary outputs 1 and 2.
There are some limitations on some output function allocations.
Output function types and allocation limitations are as described in
the following.
Identical output functions cannot be allocated doubly to the control
output 1 or 2 and auxiliary output 1 or 2.
Standard Models
Assignment
Destination
Control Output
Auxiliary Output
Destination
Output Function
1
2
1
2
Control output (heat)
(see note 1)
Yes
Yes
No
No
Control output (cool)
(see note 1)
Yes
Yes
No
No
Alarm 1
Yes
Yes
Yes
Yes
Alarm 2
Yes
Yes
Yes
Yes
Alarm 3
Yes
Yes
Yes
Yes
HBA (see notes 1, 2)
Yes
Yes
Yes
Yes
LBA (see note 1)
Yes
Yes
Yes
Yes
Time signal 1
Yes
Yes
Yes
Yes
Time signal 2
Yes
Yes
Yes
Yes
Program end
Yes
Yes
Yes
Yes
Stage output
(see note 1)
Yes
Yes
Yes
Yes
Error 1 : Input error
No
No
Yes
Yes
Error 2 : A/D convertor
error
No
No
Yes
Yes
Note:
1. Assignment is not possible with the control valve control
type.
2. Heater burnout alarm is not available for the E5CK.
Position-proportional Models
Position-proportional-type Controllers support nine output func-
tions. These are assigned to auxiliary outputs 1 and 2.
Restrictions on assignment destinations are placed on some of the
outputs. The following table shows where outputs may be assigned
to.
Assignment
Destination
Control Output
Auxiliary Output
Destination
Output Function
1
2
1
2
Alarm 1
No
No
Yes
Yes
Alarm 2
No
No
Yes
Yes
Alarm 3
No
No
Yes
Yes
Time signal 1
No
No
Yes
Yes
Time signal 2
No
No
Yes
Yes
Stage output
No
No
Yes
Yes
Program end output
No
No
Yes
Yes
Error 1 : Input error
No
No
Yes
Yes
Error 2 : A/D converter
error
No
No
Yes
Yes
With control output (cool), the conditions for switching from stan-
dard control to heating and cooling control are reached when the
output function is assigned at the cooling side during heating and
cooling control.
In other words, heating and cooling control is carried out when con-
trol output (cool) is assigned, and standard control is carried out
when output is not assigned.