E3X-DA-S
20
✽
The detection settings and MODE Key settings are the same for channel 1 and channel 2.
Other functions can be set separately for each channel.
Setting F
u
nctions (SET Mode)
5
Mo
v
ing
b
et
w
een F
u
nctions
11. External inp
u
t memory
(Refer to the
Instruction Manual
pro
v
ided
w
ith the sensor.)
SET
Set the SET/RU
N
Mode
Selector S
w
itch to SET.
7. Display orientation
(To re
v
erse the orientation of
the display.)
6. Display s
w
itch
(To change the display method)
4. ATC setting
(To change the ATC setting)
8
. ECO Mode
(To set the ECO Mode)
9. O
u
tp
u
t setting
(To change o
u
tp
u
ts for
channel 2)
10. External inp
u
t
(To change f
u
nctions controlled
u
sing the external inp
u
t)
RUN
Set the SET/RU
N
Mode
Selector S
w
itch to RU
N
.
W
hen the
settings ha
v
e
b
een completed
2. Timer
(To
u
se the timer setting)
0. Operation mode
(To set the operation mode)
5. MODE Key
(To change the f
u
nction of the
MODE Key d
u
ring operation)
3. Teaching le
v
el
(To change the teaching le
v
el)
1. Detection
(To change response speed and
detection precision)
Teaching
MODE
✽
The f
u
nction transition
b
oxes sho
w
the defa
u
lt settings.
✽
More f
u
nctions may
b
e displayed depending on the detailed settings.
➜
Refer to
4. Teaching the
Threshold
on page 19.
Setting (display)
F
u
nction
✽
Description
Used to change the response speed or detection precision.
1. Detection
✽
S
u
per-high-speed: , High-speed: , Standard: ,
High-resol
u
tion: , To
u
gh: , Differential operation:
Use the UP and DO
WN
Keys to change the settings.
UP
DOWN
Light O
N
: , Dark O
N
:
0. Operation mode
Used to set the differential response time.
Single edge: , Do
ub
le edge:
Differential edge
(differential operation
selected)
Used to set the edge to
b
e detected.
Differential time
Single edge···250
µ
s: , 500
µ
s: , 1 ms: , 10 ms: , 100 ms: ,
Do
ub
le edge···500
µ
s: , 1 ms: , 2 ms: , 20 ms: , 200 ms:
4. ATC setting
Setting at Po
w
er-O
N
(ATC O
N
)
Used to ena
b
le or disa
b
le the ATC f
u
nction.
Used to set the processing to
b
e performed
w
hen the
po
w
er is t
u
rned O
N
.
ATC ena
b
led: , ATC disa
b
led:
N
o setting: , ATC start processing: ,
Po
w
er t
u
ning and ATC start processing:
F
u
nctions
Timer disa
b
led: , OFF-delay timer: ,
O
N
-delay timer: , One-shot timer:
O
N
-delay + OFF-delay timer:
2. Timer
1 to 20 ms: 1-ms increments, 20 to 200 ms: 10-ms increments,
200 ms to 1 s: 100-ms increments, 1 to 5 s: 1-s increments
Time
(timer ena
b
led)
Used to change timer settings
w
hen timers are ena
b
led.
The timer can
b
e set from 1 to 5,000 ms.
Used to ena
b
le or disa
b
le timers.
Exec
u
tes po
w
er t
u
ning: ,
Exec
u
tes a zero reset: , T
w
o-point teaching: ,
A
u
tomatic teaching: , ATC start:
Setting range: 100 to 3,900 (increments of 100)
Maxim
u
m po
w
er :
5. MODE Key
✽
Po
w
er t
u
ning target
v
al
u
e
(performing po
w
er t
u
ning)
Used to change the f
u
nction of the MODE Key d
u
ring RU
N
operation.
Used to set target
v
al
u
es d
u
ring po
w
er t
u
ning.
3. Teaching le
v
el
Setting range: to
Used to change the threshold setting
w
hen teaching a
Thro
u
gh-
b
eam Fi
b
er Unit
w
itho
u
t a
w
orkpiece or teaching
a Reflecti
v
e Fi
b
er Unit
w
itho
u
t a
w
orkpiece.
➜
Refer to
1. Setting the Operation Mode
on page 18.
➜
Refer to
2. Adjusting the Power
on page 18.